4
4
4-58
4-58
Disassembly/Assembly > Controller System > Removing the NCU PCB > Procedure
Disassembly/Assembly > Controller System > Removing the NCU PCB > Procedure
* The Main Controller Board is shipped with the jumper connector of the lithium battery
OFF.
Make the following adjustments:
Correction of output between CS channels
1) Enter the service mode.
2) Input values on the service label attached to the controller exhaust fan mount.
Input this value
After completion of the above procedure, the contact sensor output is compensated and
parameters are set automatically.
•
F-4-121
Removing the NCU PCB
Preparations
1) Removing the Left Cover.
2) Removing the Controller Cover.(Refer to page 4-55)
Procedure
1) Remove the Flat Cable [1].
[1]
2) Remove the NCU PCB [1].
3 Screws [2]
[1]
[2]
[2]
x3
■
■
•
F-4-122
F-4-123