8
8
8-9
8-9
Service Mode > Service Soft Switch Settings (SSSW) > SSSW-SW12 > List of Functions
Service Mode > Service Soft Switch Settings (SSSW) > SSSW-SW12 > List of Functions
SSSW-SW05
List of Functions
Bit
Function
1
0
0
not used
-
-
1
Conversion from mm to inch
(text mode)
convert
do not convert
2
Conversion from mm to inch
(text/photo mode)
convert
do not convert
3
not used
-
-
4
not used
-
-
5
not used
-
-
6
not used
-
-
7
not used
-
-
Detailed Discussions of Bit 1
Use it to enable/disable millimeter/inch conversion in sub scanning direction for images
read in text mode.
Scanning direction in conversion follows the Bit 2 setting of SW14.
Detailed Discussions of Bit 2
Use it to enable/disable millimeter/inch conversion in sub scanning direction for images
read in text/photo mode while bit 1 is set to '1'.
Scanning direction in conversion follows the Bit 2 setting of SW14.
SSSW-SW12
List of Functions
Bit
Function
1
0
0
Time-out period for one page upon
transmission
1
0
1
Time-out period for one page upon
transmission
1
0
2
not used
-
-
3
not used
-
-
4
Time-out period for one page upon
reception
1
0
5
Time-out period for one page upon
reception
1
0
6
not used
-
-
■
■
■
■
T-8-20
T-8-20
Bit
Function
1
0
7
Respective page timer settings for
transmission and for reception
enable
do not enable
The machine will stop the ongoing communication if the transmission/reception of a single
original page takes 32 min or more. To use the timer for a purpose other than this function,
refer to the tables that follow, and select an appropriate time length.
When 'do not enable' is selected using bit 7, the time-out length for a single page for all
modes will depend on the setting of bit 0 and bit 1.
Time-Out Length for
Transmission/Reception
Bit7 Bit6
Bit5
Bit4 Bit3 Bit2 Bit1 Bit0
8 min
0
*
*
*
*
*
0
0
16 min
0
*
*
*
*
*
0
1
32 min
0
*
*
*
*
*
1
0
64 min
0
*
*
*
*
*
1
1
Time-Out Length for Transmission
(in text mode)
Bit7 Bit6
Bit5
Bit4 Bit3 Bit2 Bit1 Bit0
8 min
1
*
*
*
*
*
0
0
16 min
1
*
*
*
*
*
0
1
32 min
1
*
*
*
*
*
1
0
64 min
1
*
*
*
*
*
1
1
Time-Out Length for
Reception
Bit7
Bit6 Bit5
Bit4 Bit3
Bit2
Bit1 Bit0
8 min
1
*
0
0
*
*
*
*
16 min
1
*
0
1
*
*
*
*
32 min
1
*
1
0
*
*
*
*
64 min
1
*
1
1
*
*
*
*
T-8-21
T-8-21
T-8-22
T-8-22
T-8-23
T-8-23
Содержание mf6600 Series
Страница 15: ...1 1 Product Overview Product Overview Product Lineups Product Features Specifications Name of Parts ...
Страница 167: ...5 5 Adjustment Adjustment Scanning System Adjustment Electrical Adjustment ...
Страница 170: ...6 6 Trouble Shooting Trouble Shooting Test Print Trouble Shooting Items Version Up ...
Страница 182: ...7 7 Error Codes Error Codes Error Code Fax Error Code ...
Страница 223: ... Appendex Appendex Service Tools Solvents and Oil List General Timing Chart General Circuit Diagram Appendex ...