75
Specsheet for “RS232 by TELNET”:
■
Telnet: TCP
■
Telnet port: 7000
■
Telnet utility: Windows “TELNET.exe” (console mode)
■
Disconnection for RS232-by-Telnet control normally: Close Windows Telnet utility directly after
TELNET connection ready
■
Limitation 1 for Telnet-Control: there is only one connection for Telnet-Control in one projector
Limitation 2 for Telnet-Control: there is less than 50 bytes for successive network payload for
Telnet-Control application.
Limitation 3 for Telnet-Control: there is less than 26 bytes for one complete RS232 command for
Telnet-Control.
Limitation 4 for Telnet-Control: Minimum delay for next RS232 command must be more than 200
(ms).
(* In Windows built-in “TELNET.exe” utility, “Enter” key pressed will have “Carriage-Return” and
“New-Line” code.)