8.2 Transfer Example
Get input mode for the projector by basic commands.
COMMAND
(
(current input mode command issue)
)
PC
Æ
Projector “C” ”R” ”1” CR
Projector
Æ
PC ”1” CR
←―――→
Response
(A few ms--1s)
(Shows
Computer 1 is selected)
8.3 Status Read Command
Command “CR0” [CR]
Detail
Get the projector status
Acceptable
“%1” [CR]
%1
“00” = POWER ON
“80” = STANDBY
“40” = Processing Count Down
“20” = Processing Cooling Down
“10” = Power Failure
“28” = Processing cooling down due to abnormal temperature
“08” = Abnormal Temperature
“88” = normal after recovering abnormal temperature
“02” = cannot accept RS232C command
“24” = Processing Power Save
・
Cooling Down
“04” = Power Save
Response
Unacceptable “?” [CR]
【
Response Detail
】
8.3.1 “00” [CR]
Status: POWER ON
The image is displayed normally.
8.3.2 “80” [CR]
Status: STAND BY
When the status is STAND BY, Status Read Commands are always acceptable, but
Functional Execution Commands are not acceptable except Power ON Command
Page
17/21