● Procedure for Importing from a PC
1. Prepare the setting information file (".dcm" file) to import.
2. Access the following service mode in the Remote UI from a PC browser, specify the file to import, enter the
encryption password, and click [Start Importing].
• SERVICE MODE > FUNCTION GR. > Import/Export Set. > IMPORT
3. When the following message is displayed after the processing is complete, click [Restart].
4. Restart this machine, enter service mode, and confirm that the setting information is reflected.
This completes the procedure for importing a setting information file.
Backup/Restoration Using a Function Other Than the DCM Function
This machine is equipped with functions other than the DCM function for migrating data to an unused Main Controller PCB when
the Main Controller PCB has failed.
Backup Method
This machine is equipped with the following backup methods other than the DCM function.
Backup Method
Items which can be backed up
USB
Setting Value(USER MODE, SERVICE MODE, etc)
Expansion ROM for
servicing/Sublog Board
Setting Value(USER MODE, SERVICE MODE, etc)
Management Data (Page Counter, Main Controller service counter, Serial No.)
■ Backup to/Restoration from a USB Flash Drive Using Service Mode
You can use service mode to back up settings information to a USB flash drive and restore data backed up to a USB flash drive,
without using the DCM function.
Target Data for Backup
• [Settings/Registration] menu setting values
• Service mode setting values
● Backing Up to a USB Flash Drive
This section describes the procedure for backing up to a USB flash drive.
1. Connect the USB flash drive to the USB Memory Port of this machine.
3. Technical Explanation (System)
80
Содержание LBP351 Series
Страница 1: ...Revision 4 0 LBP351 352 Series Service Manual ...
Страница 12: ...Product Overview 1 Product Lineups 6 Specification 7 List of Parts 11 ...
Страница 115: ...Periodical Service 4 Periodically Replaced Parts 109 Consumable parts 110 Periodical Service 111 ...
Страница 118: ...Periodical Service Periodical Service No periodic services are required to this machine 4 Periodical Service 111 ...
Страница 140: ...3 Remove the Main Drive Unit 1 4 Screws 2 1 2 2 2 2 4x 5 Parts Replacement and Cleaning 133 ...
Страница 147: ...Adjustment 6 Actions after Replacement 141 ...
Страница 149: ...Troubleshooting 7 Test Print 143 Troubleshooting 147 Obtaining Debug Log 149 ...
Страница 160: ...Error Jam Alarm 8 Overview 154 Error Code Details 155 Jam Code 160 Alarm Code 163 ...
Страница 170: ...Alarm Code Alarm Code Details Cause 06 0002 Fixing Assembly Alarm Fixing Assembly Life 8 Error Jam Alarm 163 ...
Страница 171: ...Service Mode 9 Overview 165 Service Mode 169 ...