3. The following message is displayed when backup is completed successfully.
195$0H[SRUWFRPSOHWH
4. Turn OFF the power, and remove the faulty Main Controller PCB and the Sublog Board to which data was exported.
CAUTION:
Since data cannot be migrated to a Main Controller PCB that has been used before, connect an unused Main Controller
PCB to the Sublog Board and Expansion ROM PCB where the data has been backed up (exported to) before installing it
to the machine.
A Main Controller PCB that has been connected to a machine and powered ON even once becomes a used PCB.
Restoration Procedure (Import)
1. Connect the Sublog Board with the Expansion ROM for servicing which has data exported, to an unused Main
Controller PCB.
2. Install the unused Main Controller PCB to the machine, and turn ON the power.
3. Perform the following operation to write the information saved in the Sublog Board back to the machine.
195$0LPSRUW㻈㻉
1. Press the right arrow key on the Control Panel.
2. Select [NVRAM import].
3. Press the down arrow key.
4. If the import processing completes without a problem, the data saved on the Sublog Board is deleted and the
following message is displayed.
3. Technical Explanation (System)
85
Содержание LBP351 Series
Страница 1: ...Revision 4 0 LBP351 352 Series Service Manual ...
Страница 12: ...Product Overview 1 Product Lineups 6 Specification 7 List of Parts 11 ...
Страница 115: ...Periodical Service 4 Periodically Replaced Parts 109 Consumable parts 110 Periodical Service 111 ...
Страница 118: ...Periodical Service Periodical Service No periodic services are required to this machine 4 Periodical Service 111 ...
Страница 140: ...3 Remove the Main Drive Unit 1 4 Screws 2 1 2 2 2 2 4x 5 Parts Replacement and Cleaning 133 ...
Страница 147: ...Adjustment 6 Actions after Replacement 141 ...
Страница 149: ...Troubleshooting 7 Test Print 143 Troubleshooting 147 Obtaining Debug Log 149 ...
Страница 160: ...Error Jam Alarm 8 Overview 154 Error Code Details 155 Jam Code 160 Alarm Code 163 ...
Страница 170: ...Alarm Code Alarm Code Details Cause 06 0002 Fixing Assembly Alarm Fixing Assembly Life 8 Error Jam Alarm 163 ...
Страница 171: ...Service Mode 9 Overview 165 Service Mode 169 ...