9) Joint the supplied relay harness to the connectors of the finisher controller PCB and
the additional tray driver PCB.
x2
F-6-15
F-6-15
10) Fix the inner front cover removed in Step 5 with the 3 screws.
x3
F-6-16
F-6-16
11) Put the upper guide as shown in the figure paying attentionto the safety switch sensor unit.
Then fix it with 6 screws. (Stepped screw x 2, Binding screw x 4)
MEMO:
Confirm that the harness fixed at the step 10) does not come out of the upper guide.
Stepped screw
x6
F-6-17
F-6-17
12) Fix the screw to secure the safety switch sensor unit.
x1
F-6-18