COPIER > OPTION > FNC-SW
AMSOFFSW
1
Enabling of AMS mode
Detail
To enable the AMS mode.
When 0 is set, the AMS mode is enabled. The AMS mode is automatically enabled when the
following 2 conditions are satisfied.
- AMS license for an iR option is installed.
- AMS-supported Login application (User Authentication, etc.) is activated.
Use Case
When enabling AMS mode
Adj/Set/Operate Method
1) Check that AMS-supported Login application is activated.
2) Enter 0, and then press OK key.
3) Turn OFF/ON the main power switch.
4) Check that [Role Management] is displayed on remote UI.
Display/Adj/Set Range
0 to 1
0: AMS mode enabled, 1: AMS mode disabled
Default Value
1
Related Service Mode
COPIER> OPTION> LCNS-TR> ST-AMS
Additional Functions
Mode
(Remote UI) User Management> Authentication Management> Role Management
Supplement/Memo
AMS: Access Management System
In AMS mode, [Role Management] is displayed on remote UI.
UA-OFFSW
1
ON/OFF of unified auth function
Detail
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set ON/OFF of the Unified Authentication function.
Set 0 when not preferring to use the Unified Authentication function because of security concern.
Use Case
Upon user's request (not to use the Unified Authentication function)
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: ON, 1: OFF
Default Value
0
Supplement/Memo
Unified Authentication: A function with which it is considered that login authentication under it is
performed by logging in it using SSO-H.
MIB-NVTA
1
RFC-compatible character stringMIB write
Detail
As default, MIB object which NVT-ASCII can be written exists in order to link with LUI entry value.
This violates RFC order, so a problem like garbled 2-byte characters may occur in the SNMP
monitoring system, such as the 3rd vendor's MPS.
Whether non-RFC-compatible character strings are written in MIB can be set using this mode.
When 1 is set, only the character strings which are strictly compatible with RFC are written. (Writing
operation is executed from the SNMP manager.) LUI is not linked.
Use Case
Upon user's request (operation with RFC-compatible system)
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 3
0: Compatible in a conventional manner, 1: RFC-compatible, 2 to 3: Not used
Default Value
0
Supplement/Memo
RFC: Document of internet-related technical standards
NVT-ASCII: Network Virtual Terminal-ASCII
MIB-EXT
1
For R&D
8. Service Mode
911
Содержание imageRUNNER ADVANCE C5500 Series
Страница 1: ...Revision 2 0 imageRUNNER ADVANCE C5500 Series Service Manual ...
Страница 19: ...Product Overview 1 Product Lineup 6 Features 11 Specifications 15 Parts Name 26 ...
Страница 28: ...1 Product Overview 14 ...
Страница 385: ... Procedure 1 Remove the E ring 1 and then remove the 27T Gear 2 1 2 4 Disassembly Assembly 371 ...
Страница 400: ...2 Remove the Right Rear Cover 1 1 1 Screw RS Tightening M4 2 Screws TP M3 1 Claw 1 4 Disassembly Assembly 386 ...
Страница 405: ...3 Open the Fixing Unit 1 and remove the Fixing Gear Cover 2 1 Screw 3 1x 1 2 3 4 Disassembly Assembly 391 ...
Страница 416: ... Procedure 1 Remove the Connector Cover 1 2 Screws 2 1 2 2 2x 4 Disassembly Assembly 402 ...
Страница 420: ...Adjustment 5 Pickup Feed System 407 Original Exposure System 415 Actions at Parts Replacement 428 ...
Страница 494: ...Error Jam Alarm 7 Overview 481 Error Code 484 Jam Code 629 Alarm Code 642 ...
Страница 672: ...Service Mode 8 Overview 659 COPIER 675 FEEDER 1070 SORTER 1075 BOARD 1096 ...
Страница 676: ... i Press the button to display the screen showing the locations of electrical components 8 Service Mode 662 ...
Страница 1118: ...Unpacking 1 2 1120 mm 840 mm 769 mm 1230 mm 2350 mm 3 9 Installation 1104 ...
Страница 1132: ...2 2x 3 2x 4 5 6 NOTE Although the LED Cable is disconnected in the illustration the procedure is the same 9 Installation 1118 ...
Страница 1136: ...18 19 20 21 2x 9 Installation 1122 ...
Страница 1143: ...Other Installations 1 2 NOTE Only when the Cassette Pedestal is not installe 3 4 9 Installation 1129 ...
Страница 1158: ...6 2x 7 2x 8 2x 2x 9 NOTE Use the parts removed in steps 5 6 and 7 2x 1x 4x 9 Installation 1144 ...
Страница 1159: ...10 2x 11 NOTE Use the screws and rubber caps removed in step 2 M4x10 4x 9 Installation 1145 ...
Страница 1161: ...3 3x 4 4x 5 6 NOTE Use the screws and Rubber Caps removed in step 2 2x 7 2x 9 Installation 1147 ...
Страница 1162: ...8 2x Binding M4x8 9 10 9 Installation 1148 ...
Страница 1164: ...15 Turn ON the main power switch 9 Installation 1150 ...
Страница 1167: ...7 1x 8 9 1x 10 2x 11 6x 9 Installation 1153 ...
Страница 1168: ...12 1x 13 CAUTION Be careful not to drop the washer 2x 9 Installation 1154 ...
Страница 1170: ...2 1x 3 CAUTION Be careful not to drop the washer 2x 4 1x 9 Installation 1156 ...
Страница 1171: ...5 6x 6 2x 7 1x 8 9 1x 9 Installation 1157 ...
Страница 1188: ...7 Paste the power supply label on the lower part of the AC input connector 8 Turn ON the host machine 9 Installation 1174 ...
Страница 1193: ...2 Installation Procedure 1 9 Installation 1179 ...
Страница 1196: ...3 CAUTION To avoid damage do not pull the Utility Tray too much 4 9 Installation 1182 ...
Страница 1198: ...7 2x 2x M4x8 Black When Installing the USB Keyboard 1 9 Installation 1184 ...
Страница 1203: ...11 12 13 3x 14 1x 1x Lower Cover 15 1x 9 Installation 1189 ...
Страница 1204: ...16 1x 1x 17 1x 1x 18 1x 19 TP M3x12 2x 9 Installation 1190 ...
Страница 1205: ...20 TP M3x6 4x 21 22 9 Installation 1191 ...
Страница 1209: ...Installation Procedure 1 2 2x 3 2x 4 2x 9 Installation 1195 ...
Страница 1213: ...16 17 18 19 2x 9 Installation 1199 ...
Страница 1214: ...20 2x 21 22 Connect the power plug of the host machine to the power outlet 23 Turn the main power switch ON 9 Installation 1200 ...
Страница 1217: ...4 1x 1x 5 2x Installing the Serial Interface Kit 1 1x 1x NOTE The removed screw will be used in step 3 2 1x 9 Installation 1203 ...
Страница 1218: ...3 NOTE Use the screw removed in step 1 3x 1x Installing the Copy Control interface Kit 1 2 2x 1x 9 Installation 1204 ...
Страница 1221: ...2 3 4 1x 1x 5 1x NOTE The removed screw will be used in step 7 9 Installation 1207 ...
Страница 1225: ...Installation Outline Drawing Installation Procedure 1 3x 2 3 4 1x 9 Installation 1211 ...
Страница 1226: ...5 1x 1x 6 2x 2x 7 9 Installation 1212 ...
Страница 1230: ...21 NOTE Use the screw removed in step 19 2x 22 23 24 15 0 mm 15 0 mm 25 2x 4x 9 Installation 1216 ...
Страница 1243: ...11 NOTE Affix the HDD Caution Label in the appropriate language by aligning it with the upper left corner 9 Installation 1229 ...
Страница 1252: ...3 TP M3x8 Black 2x 4 TP M3x6 2x 5 9 Installation 1238 ...
Страница 1267: ...3 TP M3x8 Black 2x 4 TP M3x6 2x 5 9 Installation 1253 ...
Страница 1284: ...Installation Outline Drawing Installation Procedure 1 3x 2 3 4 1x 9 Installation 1270 ...
Страница 1285: ...5 1x 1x 6 2x 2x 7 9 Installation 1271 ...
Страница 1288: ...15 16 17 3x 18 19 Binding M4x16 Binding M3x16 M4x16 2x M3x16 20 Binding M4x6 1x 9 Installation 1274 ...