Chapter 9
9-8
9.3.1.2 Transparency Mode
0010-8235
In transparency mode, the machine decreases the fixing roller surface temperature to prevent wrapping of
a transparency around the fixing roller (otherwise the heat of the roller could melt the film surface).
F-9-11
SERVICE MODE:
COPIER > OPTION > BODY > OHP-TEMP
(transparency mode temperature setting switchover)
0: 198 dg C (default)
1: 193 dg C
2: 188 dg C
3: 183 dg C
9.3.1.3 Heavy Paper Mode
0010-8236
To prevent a drop in the surface temperature of the fixing roller in heavy paper mode, the machine uses a
higher down sequence shift temperature.
The machine uses heavy paper down sequence mode when 'heavy paper' is selected for the following in
user mode: common settings>paper type.
SERVICE MODE:
COPIER > OPTION > BODY > FIX-TEMP
(heavy paper down sequence start temperature setting)
COPIER > OPTION > BODY > TEMP-TBL
(heavy paper mode copy temperature setting; Jpn model
only)
To prevent down sequence from starting with the 1st sheet in heavy paper mode, the machine uses heavy
paper temperature control (in view of the fact that the Japanese model uses a control temperature of 188
deg C for printing).
Setting
iR7105
86 cpm
74 cpm
Suspend
Resume
iR7095
77.8 cpm
67 cpm
Suspend
Resume
iR7086
70 cpm
60 cpm
Suspend
Resume
0 (default)
194 deg C
193 deg C
183 deg C
198 deg C
1
189 deg C
188 deg C
178 deg C
193 deg C
2
184 deg C
183 deg C
173 deg C
188 deg C
Setting
Heavy paper copy temperature
0
+10 deg C
1 to 4
+0 deg C
Wait indication
Green
Green
Red
Fixing motor (M3)
Main heater (H1)
Sub heater (H2)
STBY
INTR
LSTR
STBY
Transparency
mode selected
Start key ON
205
200
198
193
Transparency control temperature
Controlled to
198 deg C
Controlled to
198 deg C
Continues idle rotation until
the surface temperature of
the fixing roller drops to the
transparency control temperature.
195
Controlled to
195 deg C
*If the reading of the thermistor is lower that
the transparency control temperature, printing is started as is.
for Jpn model, -10 deg C for all.
Содержание IMAGERUNNER 7086
Страница 20: ...Chapter 1 Introduction ...
Страница 46: ...Chapter 2 Installation ...
Страница 88: ...Chapter 3 Basic Operation ...
Страница 94: ...Chapter 4 Main Controller ...
Страница 116: ...Chapter 5 Original Exposure System ...
Страница 165: ...Laser Exposure Chapter 6 ...
Страница 175: ...Chapter 7 Image Formation ...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec ...
Страница 231: ...Chapter 8 Pickup Feeding System ...
Страница 287: ...Chapter 9 Fixing System ...
Страница 312: ...Chapter 10 External and Controls ...
Страница 346: ...Chapter 11 MEAP ...
Страница 350: ...Chapter 12 RDS ...
Страница 360: ...Chapter 13 Maintenance Inspection ...
Страница 375: ...Chapter 14 Standards Adjustments ...
Страница 407: ...Chapter 15 Correcting Faulty Images ...
Страница 433: ...Chapter 16 Self Diagnosis ...
Страница 460: ...Chapter 17 Service Mode ...
Страница 559: ...Chapter 18 Upgrading ...
Страница 583: ...Chapter 19 Service Tools ...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2 ...
Страница 588: ...APPENDIX ...
Страница 615: ......