Chapter 5
5-16
2. ADF Being Opened
No.1 mirror base: moves to a specific point of original detection
scanning lamp: off
original sensor: off
F-5-33
3. ADF Being Closed
No. 1 mirror base: at point of original detection
scanning lamp: off -> on
original sensor: original detection operation
- When the ADF is at 25 deg or lower, the external light within the width of any original is kept out of
external light, thus causing the machine to assume the absence of an original at points of external light
detection (external light search operation).
The ADF open/closed sensor 2 identifies the state as being "closed," and the machine starts original size
detection.
Here, B5, B4, A4, and A3 are eliminated from the list of possible sizes.
- When the external light search is over, the machine turns on the xenon lamp for the main scanning lamp,
and checks the CCD (4 points) for external light. For sub scanning direction, the machine starts to
operate the original sensor.
F-5-34
4. ADF Fully Closed (5 deg or less)
No. 1 mirror base: at point of original detection
scanning lamp: on
original sensor: original detection operation
The machine looks for a change in the output level of individual sensors for a period of 2 sec after the
ADF open/closed sensor 1 has identified the current state as being "closed." The absence of a change in
the level causes the machine to assume the presence of an original at the point in question.
The machine uses the combination of changes in the levels of 5 points to identify the size of the original
in question.
F-5-35
(external
light)
(external
light)
25
5
Содержание IMAGERUNNER 7086
Страница 20: ...Chapter 1 Introduction ...
Страница 46: ...Chapter 2 Installation ...
Страница 88: ...Chapter 3 Basic Operation ...
Страница 94: ...Chapter 4 Main Controller ...
Страница 116: ...Chapter 5 Original Exposure System ...
Страница 165: ...Laser Exposure Chapter 6 ...
Страница 175: ...Chapter 7 Image Formation ...
Страница 180: ...Chapter 7 7 3 7 3 Basic Sequence 7 3 1 Basic Sequence 0010 8038 F 7 3 ON ON WMUPR WMUP STBY OFF 100msec ...
Страница 231: ...Chapter 8 Pickup Feeding System ...
Страница 287: ...Chapter 9 Fixing System ...
Страница 312: ...Chapter 10 External and Controls ...
Страница 346: ...Chapter 11 MEAP ...
Страница 350: ...Chapter 12 RDS ...
Страница 360: ...Chapter 13 Maintenance Inspection ...
Страница 375: ...Chapter 14 Standards Adjustments ...
Страница 407: ...Chapter 15 Correcting Faulty Images ...
Страница 433: ...Chapter 16 Self Diagnosis ...
Страница 460: ...Chapter 17 Service Mode ...
Страница 559: ...Chapter 18 Upgrading ...
Страница 583: ...Chapter 19 Service Tools ...
Страница 584: ...Contents Contents 19 1 Service Tools 19 1 19 1 1 Special Tools Table 19 1 19 1 2 Solvents Oils 19 2 ...
Страница 588: ...APPENDIX ...
Страница 615: ......