CHAPTER 3 DISASSEMBLY & REASSEMBLY
3. Document Eject Tray
4. Straight Path Tray
1) Remove the roller unit and remove the
screw
{
1
(M3, self-tapping). Then, push
down the hooks
{
2
on the left and right
to unhook the fitting parts, and pull the
document eject tray out towards you.
1) Open the straight path tray
{
1
, bend the
tray with your fingers, and unhook the
fitting parts
{
2
on the right side in the
figure below. Then, unhook the fitting
parts
{
3
on the left side as well.
Note:
Once you have removed the
document eject tray, the open/close
lever inside and coil spring can also
be removed. Furthermore, the
document eject extension tray can
also be removed.
Note:
Remove from the right side as shown
in the figure below. Do not break the
tray by bending it too much.
Figure 3-107
Note:
To remove the tray without bending it,
you should remove the upper unit first.
Figure 3-106
COPYRIGHT
©