CHAPTER 5 TROUBLESHOOTING
2) Set the feed selection lever to “separate
mode” or “none separate mode” as
necessary.
3) Set the resolution, size and mode, and
then select the [Scan] button.
Note:
To set both “separate mode” and “none
separate mode”, do this twice.
4) The scanned image is displayed. (Refer
to Figure 5-257)
5) Use [Zoom] to enlarge the leading edge
of the image and ensure that the position
of the leading edge is correct. (Refer to
Figure 5-258)
Note:
If the position of the leading edge is
incorrect or the image is skewed,
perform the scan again.
Figure 5-258
6) Check the trailing edge image next and
set the adjustment values. For example,
if you want to extend by 2.0mm with A4
size, then since 2.0÷297 = 0.67%, add
“0.67” to the value. If the original value is
“0.0”, set the setting value to “0.67”. After
you have set the value, click the [Set]
button.
In the below figure, [Factory Scale for
separate mode] is set.
Figure 5-257