imageCLASS MF4890dw/MF4880dw/MF4770n Service Guide for Authorized Servicers
imageCLASS MF4890dw/MF4880dw/MF4770n Service Guide for Authorized Servicers
June 2013
Page 40
XI.
Appendix
A. Specifications
Note:
All specifications are for reference purposes only, and are subject to
change without notice.
Table 12 — Machine Specifications
Item
Description
Dimensions (H x W x D)
imageCLASS MF4890dw:
Approximately 14 1/4" x 15 3/8" x 14 1/2" (360 mm x 390 mm x
368 mm)
imageCLASS MF4880dw/MF4770n:
Approximately 14 1/4" 15 3/8" x 14 1/4" x (360 mm x 390 mm x
362 mm)
Installation Space (H x W x D)
imageCLASS MF4890dw:
Approximately 29 1/4" x 24 5/8" x 31 1/4" (741 mm x 626 mm x
793 mm)
imageCLASS MF4880dw:
Approximately 28 1/2" x 24 5/8" x 31 1/4" (723 mm x 626 mm x
793 mm)
imageCLASS MF4770n:
Approximately 28 1/2" x 24 5/8" x 29 3/4" (723 mm x 626 mm x
755 mm)
Weight (Main unit including
the toner cartridge)
imageCLASS MF4890dw: Approximately 13.4 kg (29.5 lb)
imageCLASS MF4880dw: Approximately 12.7 kg (28.0 lb)
imageCLASS MF4770n: Approximately 11.9 kg (26.2 lb)
Cartridge
Canon Cartridge 128 yields approximately 2,100 LTR pages with
the factory default print density setting.
Cartridge Type
Single cartridge system
Maximum Monthly Print
Volume
Up to 10,000 pages
Power Requirements
120 V – 127 V AC, 60 Hz, 15 A
Plug
NEMA 5-15
Power
Consumption
Operation
Approximately 520 W
Standby mode
imageCLASS MF4890dw/MF4880dw: Approximately 5.0 W
imageCLASS MF4770n: Approximately 4.5 W
Energy Saver
imageCLASS MF4890dw/MF4880dw: Approximately 2.1 W
imageCLASS MF4770n: Approximately 1.3 W
main power
switch turned
OFF
0.5 W or less
Noise Level
During Operation: 6.6 B or less (sound power),
51 dB or less (sound pressure)
During Standby:
4.3 B or less (sound power),
Inaudible (sound pressure)
Warm-Up Time
Approximately 13.5 seconds
Environmental Conditions
(Temperature: 23°C (73.4°F),
humidity: 65% RH (Relative Humidity); from when the machine is
turned ON using the main power switch to when the Standby
screen is displayed)
Temperature: 50°F to 86°F (10°C to 30°C)
Humidity: 20% to 80% RH (Relative Humidity) (no condensation)
8 Warm-up time may vary, depending on the installation environmental conditions.