1 - 7
3.2 Special Notes on Repair Servicing
(1) Cable wiring
Exercise caution when handling the DC connector and motor cable wiring. For wiring, be sure to use ties,
cores and dampers. Improper wiring or wiring without any ties, cores and dampers may cause printer
malfunction due to noise or electrostatic discharge.
<Cable wiring>
Fix the DC harness, PG motor cables, PG sensor
cables and CR motor cables with a tie.
Fix the PG sensor cables and
CR motor cables in the claw.
Fix the DC cables and PG
motor cables in the damper.
Fix the LF motor cables
with the core.