CHAPTER 3 ORIGINAL EXPOSURE SYSTEM
Figure 3-B503
Figure 3-B504
Figure 3-B505
[1]
[1]
[2]
[3]
Front
[3]
Rear
2.
Scanner Drive Cable
a.
Adjusting the Tension of the Scanner
Drive Cable
Before starting the work, obtain the mirror
positioning tool (FY9-3040-000).
1) Remove the ADF.
2) Remove the right glass retainer.
3) Remove the copyboard glass.
4) Open the front cover, and remove the up-
per inside cover and the inside cover (AP
kit).
5) Remove the control panel.
6) Remove the rear cover.
7) Remove the four screws [1], and detach
the right reinforcing stay [2].
8) Remove the inverter PCB unit.
9) Move the No. 1 mirror mount until its
cable metal fixing [3] is visible through
the hole in the copier's side plate.