5
5
5-99
5-99
Adjustment > Auxiliary Adjustment > Adjusting Height of Staple Inlet Guide > Procedure
Adjustment > Auxiliary Adjustment > Adjusting Height of Staple Inlet Guide > Procedure
3) Pressing switch SW383 [1] or SW384 [2] determines adjustment level. By pressing SW383
once, the LED [3] indicates "-1" and the staple inlet guide position [4] is moved down.
In the same way, by pressing SW384 once, the LED [3] indicates "+1" and the staple inlet
guide position [5] is moved up.
• Adjustment range: +4 to -4 (0.5mm-change per unit)
NOTE:
In the case of failure as referred to above, perform adjustment in negative direction to
clear the problem.
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[1]
[2]
[3]
[4]
[5]
F-5-232
F-5-233
4) Press switch SW385 [1] again to complete this adjustment.
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[1]
F-5-234