Figure 1. AC powered HS8000    

 
This section describes the proper connection of the DC leads to the DC power terminal block on 
the HS8000.  The DC terminal block is located on the left front of the unit and is equipped with 
three screw-down lead posts. The power terminals are identified as positive (+) and negative (-), 
and they are floating inside the unit so that either may be grounded by the user if desired. The 
chassis is “earth” or ground (GND).  
 
Simply insert the DC leads to the power terminals, positive (+) and negative (-) screws. The use 
of Ground (GND) is optional and connects to the chassis of the switch. Ensure that each lead is 
securely tightened.

 

When power is applied, the green PWR LED will illuminate.

 

 

 

Figure 2. DC terminal block for the HS8000    

 

Step 3:  Management Access 

To access the user interface of the HS8000, a VT100 session must be created through 
HyperTerminal or a comparable VT100 terminal.  Connect a DB-9 EIA-232, 

null modem

 cable 

from your PC or laptop (COM 1 or any open COM port) to the console port of the switch.   
 

Содержание HS8000

Страница 1: ... QoS Telnet Password Security Port Settings Control Spanning Tree Protocol Port based VLAN BootP DHCP etc The two built in fiber ports are designed with full duplex 100Mbps switched capability and the six copper RJ 45 ports come with full half duplex 10 100 auto negotiating ability Parts List 1 x HS8000 S MP62 AC Six UTP ports two 20km singlemode optical ports AC power or 1 x HS8000 S MP62 12VDC S...

Страница 2: ...g inside the unit so that either may be grounded by the user if desired The chassis is earth or ground GND Simply insert the DC leads to the power terminals positive and negative screws The use of Ground GND is optional and connects to the chassis of the switch Ensure that each lead is securely tightened When power is applied the green PWR LED will illuminate Figure 2 DC terminal block for the HS8...

Страница 3: ...e a HyperTerminal session from your laptop or terminal through the Programs Accessories Communications HyperTerminal menu Figure 3 Accessing HyperTerminal Assign an icon and a name for the session Figure 4 Connection Properties After a name and icon is assigned the COM port properties menu will appear Configure the connection settings to the following values ...

Страница 4: ... Password manager to access the user interface The MAIN MENU will appear and will allow you to make necessary configuration changes based on your selection CANOGA PERKINS CORP 20600 Prairie Street Chatsworth CA 91311 Tel 818 718 6300 E mail fiber canoga com Web www canoga com HS8000 Hardened Ethernet Switch Version 1 2 Login manager Password Figure 5 Log In screen CANOGA PERKINS CORP 20600 Prairie...

Страница 5: ...pgrade Software Serial TFTP 9 Reset Configuration to Factory Default 0 Exit This Menu Enter Selection by number Figure 7 System Configuration screen Step 7 IP Address and Parameters From the System Configuration Menu type 5 to access the IP Parameters Configuration screen To configure the IP address select 2 and type the IP address you wish to assign to the unit Press enter to accept the changes T...

Страница 6: ...r the application CANOGA PERKINS CORP HS8000 Hardened Ethernet Switch Port Menu Port Interface Speed Duplex Status 1 Fiber 100 FDX DOWN 2 RJ 45 100 FDX DOWN 3 RJ 45 100 FDX DOWN 4 RJ 45 100 HDX DOWN 5 RJ 45 100 HDX DOWN 6 RJ 45 100 HDX DOWN 7 RJ 45 100 HDX DOWN 8 Fiber 100 FDX DOWN Enter Port Number to View Config or 0 to Exit 2 Figure 9 Port Menu Port View Configuration for Port No 2 Interface RJ...

Страница 7: ...erter Connecting the HS8000 to the network is simple and straight forward Connect the fiber optic cables and UTP cables as depicted below The UTP ports are connected to other 10BaseT or 100BaseT ports Canoga Perkins recommends the use of Category 5 or better UTP cables for 100Mbps circuits Figure 11 Cable connection This concludes the initial set up of the HS8000 For detailed information on other ...

Отзывы: