The vertical condensate drain trap and the
condensate drain elbow are supplied with an
adaptor which allows the fitment of a 15 mm plastic
drain line 20mm to 15mm.
Horizontal - Flue
The Flue Terminal Box is to be installed on an external
wall and must be located so the pipes from the heater
are no longer than 15m.
Using the dimensions for the cut-out shown in
(FIG 16),
make a hole for the Flue Terminal Box Mounting
Bracket. Do not locate the Flue Terminal Box within
proximity of a chimney or any other source of foreign
gases (see
page 13 Regulatory Location).
FIG 16
Flue terminal box cut-out.
Remove the fan box from the mounting bracket. Install
the mounting bracket and the pipe location bracket into
wall opening using suitable fasteners and flexible sealant
between the wall and bracket A foam strip is included to
assist in sealing the bracket to the wall. (
FIG 17).
Using pipe and fittings supplied, route the pipe from the
heater to the pipe location bracket,
ensuring that all
horizontal sections are sloped downwards to the
Flue Terminal at a rate no less than 20mm per
1000mm.
The pipe location bracket ensures that the fan box can
be located on to the pipes. If necessary locate the flue
pipes using suitable clamps. Fig 19
FIG 18
Flue Terminal Box.
BOX
FIG 19
Pipes located in bracket
Power cable
(length 15 meters)
COMBUSTION AIR
Insert the Fan Box into the Mounting Bracket using the
Fan Box Fasteners and then mount the Fascia onto
the Fan Box.
FASCIA
FIG 20
Horizontal Flue Terminal Box layout.
The flue pipes should be suitably supported at every 2
metres with the clamps supplied.
Cannon Latitude 16
Outside Wall
Mounting Bracket
Fan Box
Fascia
Foam Tape
IN
ION INSTRUCTIONS
The Horizontal flue kit comes supplied with 3 elbows,
with additional 90 and 45 elbows and clamps being
available as optional accessories. A total of no more
than five elbows is recommended.
Flue kits will contain:
Horizontal Flue
3 x 60mm dia tubes, 3 x 80mm dia tubes
3 x clamps (one size fits all),
1 x Tee piece with condensate,
2 x 60mm elbow, 2 x 80mm elbow,
1 x 15mm condensate pipe connector,
Horizontal flue connector.
Vertical flue
4 x 80mm dia tubes, 2 x 60mm dia tubes,
2 x 80mm elbows, 2 x 60mm elbows,
3 x clamps (one size fits all),
1 x flue cowl, 1 x flue transition,
1 x vertical condensate trap,
1 x 15mm condensate pipe connector,
1 x Vertical flue transfer box.
FIG 17
Flue Terminal Box installation.
NOTE: It is important that the house membrane and wall
cavity is sealed in the vicinity of the flue terminal to ensure
there is no migration of flue products inside the house.
Содержание Latitude
Страница 2: ......
Страница 3: ...GENERAL OPERATION 35 36 34 31 30 24 23 22 21 21...
Страница 5: ......
Страница 6: ......
Страница 12: ...Weight 165kg...
Страница 14: ......
Страница 22: ...21...
Страница 23: ...22...
Страница 26: ...LOG INSTALLATION 25...
Страница 31: ...27 Remote handpiece is operating and switches heater ON and OFF 30...
Страница 35: ...31 Common for both 1M and 1 5M 34...