Once heater is aligned in cavity
frame it should be secured with fixing screws at the top
via the front extension supports and at the bottom
through the transit feet.
Once heater is aligned in cavity
frame it should be secured with fixing screws at the top
via the front extension supports and at the bottom
through the transit feet.
The inner glass panel has had a silicon impregnated glass fibre tape applied to the perimeter to permit effective
sealing. It is recommended that the suction cup supplied with the heater is utilised to pull the glass away from
the firebox. If this seal is intact when the glass is removed, the glass assembly may be refitted without reapplying
any sealant / glass ribbon. In the instance when the glass ribbon is damaged then this should be replaced.
Refitting of glassfibre ribbon seal.
The tape is a ladder type and is thinner along the middle of the tape. This permits the tape to be readily folded over
the edge of the glass. The two short sides and the top of the glass have the ribbon applied along the edge.
At the bottom of the glass the glass fibre ribbon is applied to the inner surface of the glass, ie that side of the glass
which faces into the firebox. See picture.
It is recommended that masking tape then be applied to the edge of glass ribbon tape on the surface that
will face into the heater.
Apply a thin bead of silicon sealant, 2-3 mm wide to the glass ribbon
on the sides and top edge evenly.
When applying the bead of silicone sealant run the tip of the
applicator nozzle directly on the surface of the glassfibre ribbon so
as to force the sealant into the ribbon. Take care not to have any
sealant migrate on to the glass.
Similarly on the lower glass ribbon apply a bead of silicon sealant
3 mm wade along the centre of the glass tape.
Remove the masking tape.
Use care not to touch the silicon sealant place the glass onto the
heater. Take care to ensure the glass is located centrally in the
heater.
Refit the glass clamps.
If silicone (suitable for 260 degree) sealant is required we recommend
using the following:
20
Содержание Latitude
Страница 2: ......
Страница 3: ...GENERAL OPERATION 35 36 34 31 30 24 23 22 21 21...
Страница 5: ......
Страница 6: ......
Страница 12: ...Weight 165kg...
Страница 14: ......
Страница 22: ...21...
Страница 23: ...22...
Страница 26: ...LOG INSTALLATION 25...
Страница 31: ...27 Remote handpiece is operating and switches heater ON and OFF 30...
Страница 35: ...31 Common for both 1M and 1 5M 34...