12.
13.
14.
15.
16.
17.
18.
19.
20.
SLEEP function. If this symbol does not
appear, the SLEEP function is not active. If only
the outline of the symbol appears, the SLEEP
function is active, meaning that the appliance will
switch
at the end of the countdown period set
by the user and shown by symbol 15. A Solid
black symbol indicates that you are in the
SLEEP setting menu.
PROGRAM timer function. If the symbol
does not appear, the PROGRAM timer is not
active. If only the outline of the symbol appears,
the PROGRAM timer is active. A solid black
symbol indicates that you are in the PROGRAM
timer setting menu.
Current day
Internal clock. The clock also functions as a
countdown timer when the SLEEP
function is selected.
Temperature set by user, for the heater to
achieve desired heat setting in
mode. This symbol does not appear in MANUAL
mode.
Unit of temperature measurement (Celsius -
Fahrenheit).
Symbol
room temperature.
Room temperature, as measured by remote
control's built-in sensor.
Low battery. When this symbol disappears
completely without flashing, the batteries must
be replaced.
21.
Keypad lock. Lock function prevents accidental
operation of buttons.
Menu Navigation
Press O to sequentially move through the functions
SLEEP and PROGRAM then back to MODE.
If no key is pressed for 7 seconds the display will return
back to the active MODE.
Adjusting Clock
batteries inserted: As soon as the batteries are
newly inserted the TIME display will blink. Set the current
hour, minute and day using the : button and use O to
confirm each value.
During operation: Press and hold both
and
3
seconds. The word "CLOCK" will appear on the screen
and the time settings can then be changed using the
procedure
Keypad Lock
The keypad can be locked by keeping pressed the “O”
button for 5 seconds or more. Pressing the”O” button
again for 5 seconds will unlock the keypad.
above.
7
I
Cannon Latitude
Sleep Function
The "SLEEP" function is used to turn the heater
automatically a
a set period of time. Navigate the menu to
SLEEP (see
Menu Navigation).
The SLEEP symbol will
appear in solid black when selected and the time remaining
until the unit is turned
will appear in the TIME
section. The time can be adjusted using the
button and
can be set at 15 minute intervals. To set the time, press the O
button. When the SLEEP mode has been set, the remaining
time until the heater is turned
will be shown in the TIME
DISPLAY section. Note: if STANDBY is scheduled as part of
a PROGRAM while the SLEEP function is activated,
is ignored until the SLEEP interval is complete.
However, a manual STANDBY or shut
disables previous
SLEEP command.
Change Temperature Units
With remote
press and hold the
button for at least 5
seconds and the temperature unit will change from Celsius
to Fahrenheit and vice versa.
Pilot Mode
To turn the heater to pilot mode, press and hold the
button for <1 second. The FLAME SETTING icon will
change from solid black to an outline of the icon.
Turn
To turn the heater press and hold the button
2
seconds.
Program Function
The "PROGRAM" function is used to automatically turn the
heater on and
at specific times. There are 10 weekly
programs
(FIG 5).
Programs cannot be added nor can
exisiting programs be modified.
Navigate the menu to "PROGRAM" (see
Menu
Navigation).
The PROGRAM symbol will appear solid
black when selected and the desired weekly program can
then be selected using the : button. To turn o the
program function, scroll down to "OFF". To accept the
program press the
button.
When the PROGRAM mode has been selected, the outline
of the PROGRAM symbol will be shown.
R
Rocker Switch
The rocker switch mounted on the heater enables the user to
turn the unit On or Off, bypassing the remote control. When
the rocker is used to switch the heater on it reverts to the last
heat setting the heater was operating at. If this switch is in the
OFF position and the remote is used to turn the heater on, and
the user wishes to turn the heater off, the switch needs to be
switched to the bypass position and then back to the OFF position.
automatically attempt a restart. If heater fails on
automatic restart, it will go into lock out mode. To
reactivate heater, switch the rocker switch firstly to
the ON position and then back to the OFF position.
The heater can now be started using your remote.
If the problem persists contact IXL Home.
If this happens the heater will
Содержание Latitude
Страница 2: ......
Страница 3: ...GENERAL OPERATION 35 36 34 31 30 24 23 22 21 21...
Страница 5: ......
Страница 6: ......
Страница 12: ...Weight 165kg...
Страница 14: ......
Страница 22: ...21...
Страница 23: ...22...
Страница 26: ...LOG INSTALLATION 25...
Страница 31: ...27 Remote handpiece is operating and switches heater ON and OFF 30...
Страница 35: ...31 Common for both 1M and 1 5M 34...