background image

26

NOTES

Warranty

Don’t risk your appliance warranty

Only a licensed person will give you a Compliance Certificate,
showing that the work complies with all the relevant standards.

And only a licensed person will have insurance protecting their
workmanship for 6 years.

So make sure you use a licensed person to install this appliance
and ask for your Compliance Certificate to ensure the manufac-
turers appliance warranty will be honoured.

Distributor

This appliance is designed, manufactured and distributed by:

Tel: 1300 727 421

3

The  benefit  conferred  by  this  warranty  are  in  addition  to  all  other  rights  and 
remedies  in  respect  of  the  product  that  consumers  have  under  the  Trade 
Practices Act  and  similar  laws  of  the  States  and  Territories. 

We  warrant  this  Cannon  appliance  to  be  free  of  defects  in  materials, 
workmanship  and  manufacturing  to  the  original  purchaser  for  2  years,  (10  years 
on  the  heat  exchanger)  from  the  date  of  original  purchase.  We  will,  at  our 
option  and  subject  to  the  terms  of  this  warranty,  repair  or  replace  free  of  charge 
this  Cannon  appliance  or  any  component  part,  which  upon  examination  by  us 
or  our  repair  agent  is  found  to  be  defective  in  materials,  workmanship  or 
manufacturing.  However,  this  warranty  does  not  cover  any  consumables  (if  any). 
The  purchaser  must  present  the  original  purchase  receipt  to  us  when  making 

any  claim  under  this  warranty.

This  warranty  will  not  apply  if:  (i)  a  compliance  label  or  serial  number  (as  the 
case  may  be)  has  been  removed  from  the  appliance  or  rendered  illegible;  (ii) 
the  appliance  has  been  subject  to  misuse,  abuse,  accident,  incorrect  installation 
or  non-domestic  use;  (iii)  the  appliance  has  been  modified,  tampered  with  or 
repaired  by  a  person  other  than  our  authorised  repair  agent;  (iv)  the  appliance 
is  re-installed/relocated  during  the  warranty  period.

The  purchaser  is  responsible  for  all  travelling  expenses  if  the  purchaser 
requests  any  repair  be  carried  out  at  a  place  outside  areas  normally  serviced 
by  our  repair  agents.
Should  you  require  service  on  this  appliance,  please  contact  our  service 
department  on  1300  727  421.

Enter  the  details  of  the  date  installed  and  the  Compliance  Certificate  number  in 
the  appropriate  area  on  the  rear  page  of  this  manual.

Содержание Fitzroy Inbuilt

Страница 1: ...INBUILT Natural and Propane gases Attach copy of data label here PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING THIS HEATER DON T RISK YOUR APPLIANCE WARRANTY ONLY A LICENSED PERSON WILL GIVE YOU A COMPIANCE CERTIFICATE SHOWING THAT THE WORK COMPLIES WITH ALL THE RELEVANT STANDARDS AND ONLY A LICENSED PERSON WILL HAVE INSURANCE PROTECTING THEIR WORKMANSHIP FOR 6 YEARS SO MAKE SURE YOU USE A L...

Страница 2: ...ealing the fascia Gas connections 16 Log installation 14 Gas control 17 18 Gas pressure point Gas pressure adjustment Installation tips 19 Trouble shooting 20 21 Connections Service instructions 22 24 General To replace the primary glass To replace outer glass To replace the gas control To replace the ignition module device To replace the room circulation fan To replace the fan pressure switch To ...

Страница 3: ...anty repair or replace free of charge this Cannon appliance or any component part which upon examination by us or our repair agent is found to be defective in materials workmanship or manufacturing However this warranty does not cover any consumables if any The purchaser must present the original purchase receipt to us when making any claim under this warranty This warranty will not apply if i a c...

Страница 4: ...replace installation kit must be used Heater specifications 1 4 Gas type Natural or Propane gas as indicated on data label Gas consumption 26 0 MJ hr Energy output 5 98 kW Enery star rating 4 05 stars Heater type Gas space heater approved to AS 4553 2008 Operating pressure Natural gas 0 75 kPa at burner high setting Propane gas 2 65kPa Gas regulator Integral part of controller Min inlet pressure 1...

Страница 5: ... are restrained from the front top and sides of the heater The manufacturer takes no responsibility if curtain clearance is less than 900mm and not restrained 5 Children and adults should be alerted to the hazard of high surface temperature and should take care to avoid burns or clothing ignition This appliance is not intended for use by persons including children with reduced physical sensory or ...

Страница 6: ...a second guard is required Standards This appliance meets the following standards When installed correctly Standards Australia AS NZS 3100 AS 5601 AS 4553 2008 To replace the room circulation fan 1 Remove the fascia Refer page 12 of the installation instructions 2 Remove the front screw retaining the bracket mounting the valve controls white box Move the bracket and controls to the front of the he...

Страница 7: ...urn the heater on again Remember that the fan will continue to operate for approximately 3 minutes after the OFF button has been pressed but you can turn the heater ON again without having to wait for the fan to stop operating If there is an interruption to the power supply the heater will fail safely and switch off When the power supply has been restored adopt the 20 seconds waiting rule before t...

Страница 8: ...tension cord Check polarity in the electrical supply lead to appliance Check that the sense electrode is in the flame Check that appliance is earthed correctly A check between the earth pin on the plug and an unpainted part of the appliance should see a resistance of 0 1 ohms 9 No gas to burner The gas valve should open at the same time as the igniter sparks If there is no gas to the burner when t...

Страница 9: ...be fitted The spacer can be ordered from the Cannon distributor Order specification for the spacer is BSPACERX B black finish or BSPACERX P platinum finish clearance is less Fireplace opening Check other connections are in place If the last checks are correct the ignition electrode should spark at the same time as the gas control solenoid valve opens At this point the spark electrode will activate...

Страница 10: ...ce is required An example of an installation with a flue fitted in most cases only a single skin flue is required Test the operation of the chimney before installing the new heater Be careful CANNON heaters are high efficiency products with low flue gas temperatures typically 100 C so if you are replacing an older type radiant heater with a much higher flue gas temperature 150 C or higher make sur...

Страница 11: ...e to increase pressure and anticlockwise to decrease pressure 5 Switch heater off and remove the manometer tube Tighten pressure test point by turning the captive screw fully clockwise 6 Replace plastic cap Ensure the little lug is positioned towards lower right hand side to clear the controls 7 Refit the fascia making sure not to damage the power cord or switch cable 8 Follow user instructions to...

Страница 12: ...to open the pressure point as indicated on figure 26 a and place manometer tube over the test point as per figure 26 b a b 26 3 To remove the inner glass see Fig 12 Loosen off the top horizontal screws only Completely remove the two vertical side clamps Try not to touch the front surface of the glass to avoid finger marks Remove the glass by gripping each vertical side and lifting out from the bot...

Страница 13: ...at the gas inlet pipe is fed through the hole located at the rear right hand side of the heater at the bottom Refer to figure 21 and connection dimensions in figure 23 2 With heater in position flanges should be hard against masonry Secure case flanges to the masonry Screw or bolt the flange through the slots provided figure 22 3 Connect the gas supply pipe to the copper compression fitting provid...

Страница 14: ...st be located within 1 5m of the heater For installations where the powerpoint is located outside of the enclosure locate the power cord in the fascia cut out on the left or right hand side as required For a power supply connection located inside the enclosure run the power cord through the cord access located on the rear panel at the lower left hand side by pushing the cord access plate from the ...

Отзывы: