background image

19

10

12

Installation tips

For installation into a masonry or brick fireplace WITH a flue connection, refer figure 7. For 
installation WITHOUT refer figures 8 & 9. After installation of the heater test the flue to 
confirm air vents are unobstructed. If an exhaust fan or other heating/ventilation 
appliances are present, switch them on. This is to test and ensure that there is no 
interaction between the Cannon heater and other appliances.

Refer to Australian Standard Gas Installations AS 5601:
For ‘air movement not to affect appliance’ see clause 5.3.1.
For ‘air supply to appliance’ see clause 5.4.1.
For ‘ventilation requirements’ see clause 5.4.3.

F1417 flue transition rectangular to 100mm round.
F2517 flue spigot is also required.

The flue must be rigid and self-supported. It is a 
requirement that the heater has a slip flue 
connection and can be removed without any 
restrictions.

Ø
Single skin flue.

100mm 

Heater

Install heater 
onto a solid, 
leveled base.

Seal heater 
perimeter with 
the foam tape 
supplied.

Roof cladding

600mm between top of 
cowl and nearest part of 
roof. (Also refer to AS 
5601)

Flue cowl 
approved to 
AG604

Flue clamp

Flashing

Fit two lengths of vertical flue (1.8m) before fitting 
any 45° bends. If bends are used, fit inside of flue 
pipe. Use no more than two 45° bends in the total 
flue run and maintain at least 250mm of straight 
flue pipe between the bends.

Be careful!
Installing a flue on the shortest 
wall may subject it to down 
draughts or reverse air flows 
through the heater which can be 
difficult to find a solution to.
Always adopt correct flue design 
practices.
In windy locations consider 
installation of a powerflue 
version heater or at least an anti 
down draught cowl to reduce 
any flue operation problems.
The heater has been tested and 
should operate satisfactorily 
with an optimum flue length of 
4.5 meters.
Exceeding this length may affect 
the stability of the flame pattern 
and the operation of the heater.
Contact our technical support 
department if any further advice 
is required.

An example of an installation with a flue fitted.
(in most cases only a single skin flue is required)

¡

Test the operation of the chimney before installing the new heater.

¡

Be careful! 

CANNON heaters are high efficiency products with low flue 

gas temperatures (typically 100°C) so if you are replacing an older type 
radiant heater with a much higher flue gas temperature (150°C or higher) 
make sure of the integrity of the fireplace and chimney before installing 
the new CANNON log fire.

¡

A solid, levelled and smooth base is required (fill gaps with fibreglass 

insulation if necessary).

¡

Avoid installing into large volume fireplaces and chimneys and not fitting a 

flue. (It is better to install a flue in these applications).

¡

We recommend cleaning or sweeping the chimney and fireplace before 

the installation of the heater commences.

¡

There must be a good seal around the heater, gas piping and electrical 

cable rear entry to stop any leakage of combustion products. Do not use 
adhesives or silicone sealant, the heater must be able to be easily 
removed if necessary.

¡

Install a chimney plate and cowl to the chimney opening using weather-

proof mortar to common building practice.

¡

Remove any curved firewall that slopes too far forward to the fireplace 

opening as it causes restriction to the flue path above the heater flue 
outlet.

¡

Make sure that the heater is fully commissioned and be certain to conduct 

a test of the integrity of the flue operation, taking into account any 
influences created by rangehoods, exhaust fans, central heating, etc.

¡

To avoid any unnecessary delays and inconvenience to your customer 

please contact or Technical Services Department on 

1300 727 421

 if the 

installation is unusual or you have concerns with the installation and/or 
heater operation before the installation commences.

¡

Any service requests resulting from incorrect installations are not covered 

by our warranty conditions and these calls will result in charges, usually 
to the end user, so please ensure that the installation and commissioning 
has been satisfactorily carried out before calling for any warranty service.

¡

Please make sure that your customer is fully instructed on how to operate 

the heater. 

7

Содержание Fitzroy Inbuilt

Страница 1: ...INBUILT Natural and Propane gases Attach copy of data label here PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING THIS HEATER DON T RISK YOUR APPLIANCE WARRANTY ONLY A LICENSED PERSON WILL GIVE YOU A COMPIANCE CERTIFICATE SHOWING THAT THE WORK COMPLIES WITH ALL THE RELEVANT STANDARDS AND ONLY A LICENSED PERSON WILL HAVE INSURANCE PROTECTING THEIR WORKMANSHIP FOR 6 YEARS SO MAKE SURE YOU USE A L...

Страница 2: ...ealing the fascia Gas connections 16 Log installation 14 Gas control 17 18 Gas pressure point Gas pressure adjustment Installation tips 19 Trouble shooting 20 21 Connections Service instructions 22 24 General To replace the primary glass To replace outer glass To replace the gas control To replace the ignition module device To replace the room circulation fan To replace the fan pressure switch To ...

Страница 3: ...anty repair or replace free of charge this Cannon appliance or any component part which upon examination by us or our repair agent is found to be defective in materials workmanship or manufacturing However this warranty does not cover any consumables if any The purchaser must present the original purchase receipt to us when making any claim under this warranty This warranty will not apply if i a c...

Страница 4: ...replace installation kit must be used Heater specifications 1 4 Gas type Natural or Propane gas as indicated on data label Gas consumption 26 0 MJ hr Energy output 5 98 kW Enery star rating 4 05 stars Heater type Gas space heater approved to AS 4553 2008 Operating pressure Natural gas 0 75 kPa at burner high setting Propane gas 2 65kPa Gas regulator Integral part of controller Min inlet pressure 1...

Страница 5: ... are restrained from the front top and sides of the heater The manufacturer takes no responsibility if curtain clearance is less than 900mm and not restrained 5 Children and adults should be alerted to the hazard of high surface temperature and should take care to avoid burns or clothing ignition This appliance is not intended for use by persons including children with reduced physical sensory or ...

Страница 6: ...a second guard is required Standards This appliance meets the following standards When installed correctly Standards Australia AS NZS 3100 AS 5601 AS 4553 2008 To replace the room circulation fan 1 Remove the fascia Refer page 12 of the installation instructions 2 Remove the front screw retaining the bracket mounting the valve controls white box Move the bracket and controls to the front of the he...

Страница 7: ...urn the heater on again Remember that the fan will continue to operate for approximately 3 minutes after the OFF button has been pressed but you can turn the heater ON again without having to wait for the fan to stop operating If there is an interruption to the power supply the heater will fail safely and switch off When the power supply has been restored adopt the 20 seconds waiting rule before t...

Страница 8: ...tension cord Check polarity in the electrical supply lead to appliance Check that the sense electrode is in the flame Check that appliance is earthed correctly A check between the earth pin on the plug and an unpainted part of the appliance should see a resistance of 0 1 ohms 9 No gas to burner The gas valve should open at the same time as the igniter sparks If there is no gas to the burner when t...

Страница 9: ...be fitted The spacer can be ordered from the Cannon distributor Order specification for the spacer is BSPACERX B black finish or BSPACERX P platinum finish clearance is less Fireplace opening Check other connections are in place If the last checks are correct the ignition electrode should spark at the same time as the gas control solenoid valve opens At this point the spark electrode will activate...

Страница 10: ...ce is required An example of an installation with a flue fitted in most cases only a single skin flue is required Test the operation of the chimney before installing the new heater Be careful CANNON heaters are high efficiency products with low flue gas temperatures typically 100 C so if you are replacing an older type radiant heater with a much higher flue gas temperature 150 C or higher make sur...

Страница 11: ...e to increase pressure and anticlockwise to decrease pressure 5 Switch heater off and remove the manometer tube Tighten pressure test point by turning the captive screw fully clockwise 6 Replace plastic cap Ensure the little lug is positioned towards lower right hand side to clear the controls 7 Refit the fascia making sure not to damage the power cord or switch cable 8 Follow user instructions to...

Страница 12: ...to open the pressure point as indicated on figure 26 a and place manometer tube over the test point as per figure 26 b a b 26 3 To remove the inner glass see Fig 12 Loosen off the top horizontal screws only Completely remove the two vertical side clamps Try not to touch the front surface of the glass to avoid finger marks Remove the glass by gripping each vertical side and lifting out from the bot...

Страница 13: ...at the gas inlet pipe is fed through the hole located at the rear right hand side of the heater at the bottom Refer to figure 21 and connection dimensions in figure 23 2 With heater in position flanges should be hard against masonry Secure case flanges to the masonry Screw or bolt the flange through the slots provided figure 22 3 Connect the gas supply pipe to the copper compression fitting provid...

Страница 14: ...st be located within 1 5m of the heater For installations where the powerpoint is located outside of the enclosure locate the power cord in the fascia cut out on the left or right hand side as required For a power supply connection located inside the enclosure run the power cord through the cord access located on the rear panel at the lower left hand side by pushing the cord access plate from the ...

Отзывы: