9
Gas type:
Natural or Propane gas, as indicated
on data label
Gas consumption:
26.0 MJ/hr
Energy output:
21.45 MJ/hr (5.96 KW)
Energy star rating:
4 stars
Heater type:
Approved to AS 4553:2008.
Operating pressure:
Natural gas: 0.75 kPa
(at the burner)
Propane gas: 2.65 kPa
Gas regulator:
Integral part of controller
Min. inlet pressure:
1.13 kPa (NG)
2.75 kPa (Propane)
Fan:
3 speed
Controller:
Electronic direct spark
Power requirement:
240 VAC 10 A
Power consumption:
90 VA maximum
Minimum cavity
Height: 605mm dimensions*
dimensions:
Width: 700mm
Depth: 393mm
Optional Accessories:
• Glass front
• Silver trim (comes complete with mesh guard)
• Spacer kit
• 3 sided surround
• 4 side surround in black & stainless steel
• Console kit
Overall dimensions:
Refer fig. 9.
*
Note: when installing into a mock fireplace a mock fireplace
installation kit must be used.
Heater specifications
9
Note:
The data label is located
on the fan chamber base,
rear of lower fascia.
16
16. The burner is contained
within the burner chamber.
Refer figure 27.
17. Carefully unpack the log
set. Logs are numbered as
follows:
No 1 - Left front log
No 2 - Left back log
No 3 - Right front log
No 4 - Right back log
Position the four individually numbered logs in the following order on
the burner head as shown in figure 28-31. The male locating pins on
burner head must engage with corresponding holes in the individual
logs.
a) Place log No.1 onto the 2 front left
pins on the burner head, ensuring that
the charring faces the front. Refer fig-
ure 28.
b) Place log No.2 onto the 2 left back
pins. Refer figure 29.
c) Place log No.3 on single right front
pin, ensure fork locates over log No. 2.
Refer figure 30.
d) Place log No. 4 on single right back
pin, ensure left side of log rests on de-
pression in No. 3 log. Refer figure 31.
18. Refit the inner glass, making sure not to over tighten the screws.
19. Replace front facia in reverse order.
20. Reconnect the switch loom to the electronics module.
21. Refit bottom flange.
22. Connect plug to the wall socket and switch it on.
20
27
28
Log installation
31
29
30
Advise the user in the
operation of the
heater.
Содержание FITZIB-SDSEB-NG