Cannon FITZIB-SDSEB-NG Скачать руководство пользователя страница 6

6

Operating instructions

1. Plug the power cord into the wall socket and turn on the power to the

heater, see figure 1. Refrain from using an extension cord.

2. For control layout refer to figure 2

3. To turn heater on press switch to POWER ON position. There  is a 5

second delay before the burner ignites. At this setting the burner is on

LOW and the fan speed is on LOW. Refer figure 3.

The burner will ignite on both HIGH and LOW settings.

4. To turn burner to HIGH setting, press switch for HIGH setting. Refer

figure 4.

User instructions

1

2

4

3

19

Test the operation of the chimney before installing the new heater.

Be careful!

CANNON heaters are high efficiency products with low flue gas tem-

peratures (typically 100

°

C) so if you are replacing an older type radi-

ant heater with a much higher flue gas temperature (150

°

C or higher)

make sure of the integrity of the fireplace and chimney before installing

the new CANNON log fire.

A solid, levelled and smooth base is required (fill gaps with fibreglass

insulation if necessary).

Avoid installing into large volume fireplaces and chimneys and not

fitting a flue. (It is better to install a flue in these applications).

We recommend cleaning or sweeping of the chimney and fireplace

before the installation of the heater commences.

There must be a good seal around the heater, gas piping and electrical

cable rear entry to stop any leakage of combustion products. Do not

use adhesives or silicone sealant, the heater must be able to be easily

removed if necessary.

Install a chimney plate and cowl to the chimney opening using weath-

erproof mortar to common building practice.

Remove any curved firewall that slopes too far forward to the fireplace

opening as it causes restriction to the flue path above the heater flue

outlet.

Make sure that the heater is fully commissioned and be certain to con-

duct a test of the integrity of the flue operation, taking into account any

influences created by rangehoods, exhaust fans, central heating, etc.

To avoid any unnecessary delays and inconvenience to your customer,

please contact our Technical Services Department on 1300 727 421

if the installation is unusual or you have concerns with the installation

and/or heater operation before the installation commences.

Any service requests resulting from incorrect installations are not cov-

ered by our warranty conditions and these calls will result in charges,

usually to the end user, so please ensure that the installation and com-

missioning has been satisfactorily carried out before calling for any

warranty service.

Please make sure that your customer is fully instructed on how to oper-

ate the heater.

Installation tips

Содержание FITZIB-SDSEB-NG

Страница 1: ...NSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS Cannon This heater is approved for use with Natural and Propane gases Please leave instructions with the owner INBUILT MODELS FITZIB SDSEB NG FITZIB SDSEB...

Страница 2: ...nnected Installation WITHOUT a flue connected Sealing Gas connections 15 Log installation 16 Gas control 17 18 Gas pressure point Gas pressure adjustment Installation tips 19 Trouble shooting 20 21 Co...

Страница 3: ...with manufacturer s instruc tions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required installation M...

Страница 4: ...e heater 4 Keep curtains clothing furniture and other flammable materials at least 900mm from front and sides of the heater At the owner s discretion curtain clearance can be less than 900mm as long a...

Страница 5: ...liances are present switch them on This is to test that there is no interaction between the Cannon heater and other appliances Refer AS5601 For air movement not to affect appliance see clause 5 3 1 Fo...

Страница 6: ...layout refer to figure 2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW Refe...

Страница 7: ...ting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the burner fails to ignite wait 20 seconds and repeat the ignition procedure Refer figure 8 To turn...

Страница 8: ...pplier or authorised service person listed in this manual Flame characteristics The heater flame should be stable no lifting from the burner and the logs should glow after approximately 15 minutes ope...

Страница 9: ...speed Controller Electronic direct spark Power requirement 240 VAC 10 A Power consumption 90 VA maximum Minimum cavity Height 605mm dimensions dimensions Width 700mm Depth 393mm Optional Accessories...

Страница 10: ...niture and curtains refer to warning on page 4 For minimum clearances refer figures 10 and 11 Note Ensure that the combustion air opening under the heater is not obstructed A CLEARANCE OF 50mm MUST BE...

Страница 11: ...m air vents are unobstructed If an exhaust fan or other heating appliances are present switch them on This is to test that there is no interaction between the Cannon heater and other appliances Refer...

Страница 12: ...12 Installation WITHOUT a flue connected 13 14...

Страница 13: ...n is to be carried out only by a qualified electrician 7 Remove the lower front cover by unscrewing two M5 screws from the air intake slot Refer figure 16 If unit is fitted with supply flexible cord e...

Страница 14: ...s in top clamp and remove side clamps Refer figure 21 Sealing 12 All gaps between heater case and fireplace are to be sealed Seal with foam tape around top and sides of heater flange as required Refer...

Страница 15: ...tion flanges should be hard against masonry Se cure case flanges to the masonry Refer figure 25 15 Connect incoming gas supply pipe to regulator For inlet position see figure 26 Close gate over gas su...

Страница 16: ...on the burner head ensuring that the charring faces the front Refer fig ure 28 b Place log No 2 onto the 2 left back pins Refer figure 29 c Place log No 3 on single right front pin ensure fork locate...

Страница 17: ...e point is closed with a captive screw Turn screw 6 revo lutions anticlockwise to open the pressure point as indicated on figure 34 a and place manometer tube over the test point as per figure 34 b Ga...

Страница 18: ...y clockwise Replace plastic cap Ensure the little lug is positioned towards lower right hand side to clear the control 28 Refit the lower front cover making sure not to damage the power cord 29 Follow...

Страница 19: ...sary Install a chimney plate and cowl to the chimney opening using weath erproof mortar to common building practice Remove any curved firewall that slopes too far forward to the fireplace opening as i...

Страница 20: ...s maxi mum until the flame has been established Terminal 14 white wire into the 8 way switch connector will be energised as soon as the flame has been sensed 5 Confirm spark is produced A blue spark c...

Страница 21: ...will go into lockout if the flame current sensitivity is less than 0 5 micro amps The approximate signal strength on high flame is about 10 micro amps and on low 4 micro amps The signal strength will...

Страница 22: ...nition device needs to be removed to allow re moval of the gas control Remove LH screw from front lower section of ignition device Remove screw from front of rectifier lead located below domed cap on...

Страница 23: ...nergise dependant on room temperature The burner should now operate on high setting To replace the fan pressure switch 1 Remove the lower fan cover by unscrewing two M5 screws through the air intake s...

Страница 24: ...appliance or spare parts contact the CANNON distributor Sampford IXL 52 70 Sparks Avenue Fairfield Vic 3078 Phone 1300 727 421 Fax 1300 727 425 email service sampfordixl com au Wiring diagram Data pl...

Отзывы: