Cannon FITZIB-SDSEB-NG Скачать руководство пользователя страница 1

USER INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SERVICE INSTRUCTIONS

Cannon

This heater is approved for use with Natural and Propane gases.

Please leave instructions with the owner

INBUILT MODELS
FITZIB-SDSEB-NG
FITZIB-SDSEB-LP

FITZROY INBUILT

24

For service to this appliance

For service to this appliance or spare parts

contact the CANNON distributor.

Sampford IXL

52 - 70 Sparks Avenue

Fairfield, Vic, 3078

Phone:

1300 727 421

Fax:

1300 727 425

email:

[email protected]

Wiring diagram

Data plate

Part No: F2903

Revision F - 2009

Cannon

FITZROY INBUILT

Содержание FITZIB-SDSEB-NG

Страница 1: ...NSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS Cannon This heater is approved for use with Natural and Propane gases Please leave instructions with the owner INBUILT MODELS FITZIB SDSEB NG FITZIB SDSEB...

Страница 2: ...nnected Installation WITHOUT a flue connected Sealing Gas connections 15 Log installation 16 Gas control 17 18 Gas pressure point Gas pressure adjustment Installation tips 19 Trouble shooting 20 21 Co...

Страница 3: ...with manufacturer s instruc tions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required installation M...

Страница 4: ...e heater 4 Keep curtains clothing furniture and other flammable materials at least 900mm from front and sides of the heater At the owner s discretion curtain clearance can be less than 900mm as long a...

Страница 5: ...liances are present switch them on This is to test that there is no interaction between the Cannon heater and other appliances Refer AS5601 For air movement not to affect appliance see clause 5 3 1 Fo...

Страница 6: ...layout refer to figure 2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW Refe...

Страница 7: ...ting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the burner fails to ignite wait 20 seconds and repeat the ignition procedure Refer figure 8 To turn...

Страница 8: ...pplier or authorised service person listed in this manual Flame characteristics The heater flame should be stable no lifting from the burner and the logs should glow after approximately 15 minutes ope...

Страница 9: ...speed Controller Electronic direct spark Power requirement 240 VAC 10 A Power consumption 90 VA maximum Minimum cavity Height 605mm dimensions dimensions Width 700mm Depth 393mm Optional Accessories...

Страница 10: ...niture and curtains refer to warning on page 4 For minimum clearances refer figures 10 and 11 Note Ensure that the combustion air opening under the heater is not obstructed A CLEARANCE OF 50mm MUST BE...

Страница 11: ...m air vents are unobstructed If an exhaust fan or other heating appliances are present switch them on This is to test that there is no interaction between the Cannon heater and other appliances Refer...

Страница 12: ...12 Installation WITHOUT a flue connected 13 14...

Страница 13: ...n is to be carried out only by a qualified electrician 7 Remove the lower front cover by unscrewing two M5 screws from the air intake slot Refer figure 16 If unit is fitted with supply flexible cord e...

Страница 14: ...s in top clamp and remove side clamps Refer figure 21 Sealing 12 All gaps between heater case and fireplace are to be sealed Seal with foam tape around top and sides of heater flange as required Refer...

Страница 15: ...tion flanges should be hard against masonry Se cure case flanges to the masonry Refer figure 25 15 Connect incoming gas supply pipe to regulator For inlet position see figure 26 Close gate over gas su...

Страница 16: ...on the burner head ensuring that the charring faces the front Refer fig ure 28 b Place log No 2 onto the 2 left back pins Refer figure 29 c Place log No 3 on single right front pin ensure fork locate...

Страница 17: ...e point is closed with a captive screw Turn screw 6 revo lutions anticlockwise to open the pressure point as indicated on figure 34 a and place manometer tube over the test point as per figure 34 b Ga...

Страница 18: ...y clockwise Replace plastic cap Ensure the little lug is positioned towards lower right hand side to clear the control 28 Refit the lower front cover making sure not to damage the power cord 29 Follow...

Страница 19: ...sary Install a chimney plate and cowl to the chimney opening using weath erproof mortar to common building practice Remove any curved firewall that slopes too far forward to the fireplace opening as i...

Страница 20: ...s maxi mum until the flame has been established Terminal 14 white wire into the 8 way switch connector will be energised as soon as the flame has been sensed 5 Confirm spark is produced A blue spark c...

Страница 21: ...will go into lockout if the flame current sensitivity is less than 0 5 micro amps The approximate signal strength on high flame is about 10 micro amps and on low 4 micro amps The signal strength will...

Страница 22: ...nition device needs to be removed to allow re moval of the gas control Remove LH screw from front lower section of ignition device Remove screw from front of rectifier lead located below domed cap on...

Страница 23: ...nergise dependant on room temperature The burner should now operate on high setting To replace the fan pressure switch 1 Remove the lower fan cover by unscrewing two M5 screws through the air intake s...

Страница 24: ...appliance or spare parts contact the CANNON distributor Sampford IXL 52 70 Sparks Avenue Fairfield Vic 3078 Phone 1300 727 421 Fax 1300 727 425 email service sampfordixl com au Wiring diagram Data pl...