Cannon FITZIB-SDSEB-NG Скачать руководство пользователя страница 2

2

Contents

Contents

2

Warranty

3

Distributor

Safety warnings

4-5

What to do if you smell gas

Warnings

Standards

User instructions

6-8

Operating instructions

Cleaning

Flame characteristics

Heater specifications

9

Installation instructions

10-14

Clearances

Fitment of cabinet depth spacer

Installation into a masonry/brick or mock fireplace

Installation WITH a flue connected

Installation WITHOUT a flue connected

Sealing

Gas connections

15

Log installation

16

Gas control

17-18

Gas pressure point

Gas pressure adjustment

Installation tips

19

Trouble-shooting

20-21

Connections

Service instructions

22-24

General

To replace the primary glass

To replace outer glass

To replace the gas control

To replace  the ignition (module) device

To replace the room circulation fan

To replace the fan pressure switch

To remove the heat exchanger

To replace the burner and spark/sense electrode

Wiring diagram

Data plate

For service to this appliance

23

the air intake slot. Refer page 13, figure 16, of the installation

instructions.

2. Disconnect the fan plug from the plug carrier. Remove the two M5

wing nuts which locate the fan to the fan chamber underside. Lower

fan from male thread.

3. Disconnect the silicon tube from the fan pressure switch, rotate the

fan scroll 90

°

 and remove the silicon tube from the venturi located

in the fan scroll. Remove fan from fan chamber.

4. Replacement fan. Remove the blanking piece from the fan scroll.

Remove the venturi and bracket from the fan removed from the

heater. Insert and secure the venturi and bracket on replacement

fan.

5. Insert fan into fan chamber ensuring that the venturi is not disturbed.

Replace silicon tube onto the venturi and locate fan onto male thread.

Secure with M5 wing nuts, ensuring rubber buffer locates over thread.

6. Replace silicon tube onto fan pressure switch and reconnect fan

plug into plug carrier.

7. Test operation of room circulation fan and fan pressure switch - turn

heater on high burner, low fan. The room fan should operate instan-

taneously and a possible 5 - 10 second delay for the fan pressure

switch to energise dependant on room temperature. The burner

should now operate on high setting.

To replace the fan pressure switch

1. Remove the lower fan cover by unscrewing two M5 screws through

the air intake slot. Refer page 13, figure 16, of the installation

instructions.

2. Remove the connecting wiring (3) from the pressure switch.
3. Remove the silicon tube from the pressure switch.
4. The pressure switch is secured onto the rear of the fan chamber

housing by four M4 screws. Remove screws.

5. Replace in reverse order.

To remove the heat exchanger

Please refer to manufacturer. Contact details page 3 of this manual.

To replace the burner and spark/sense electrodes

1. Refer pages 13 and 14, steps 7 to 11, of the installation instruc-

tions.

2. Remove the logs from the burner chamber.
3. Remove the burner chamber front, 4 screws.
4. Disconnect the 16mm nut at the outlet of the gas control.
5. Disconnect the spark and sense electrodes from the ignition (mod-

ule) device.

6. Remove the burner fixing brackets (2) from the RH and LH side of

the burner. Lift the burner assembly upward and carefully remove

from the burner chamber.

7. Replace in reverse order checking location of spark/sense elec-

trodes, refer page 21, figure 37. Spark gap between electrode

and surface of burner is 4 - 6mm. Check for gas tightness. For log

placement refer page 16 of this manual.

Содержание FITZIB-SDSEB-NG

Страница 1: ...NSTALLATION INSTRUCTIONS SERVICE INSTRUCTIONS Cannon This heater is approved for use with Natural and Propane gases Please leave instructions with the owner INBUILT MODELS FITZIB SDSEB NG FITZIB SDSEB...

Страница 2: ...nnected Installation WITHOUT a flue connected Sealing Gas connections 15 Log installation 16 Gas control 17 18 Gas pressure point Gas pressure adjustment Installation tips 19 Trouble shooting 20 21 Co...

Страница 3: ...with manufacturer s instruc tions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this product and compliance certificate as proof of required installation M...

Страница 4: ...e heater 4 Keep curtains clothing furniture and other flammable materials at least 900mm from front and sides of the heater At the owner s discretion curtain clearance can be less than 900mm as long a...

Страница 5: ...liances are present switch them on This is to test that there is no interaction between the Cannon heater and other appliances Refer AS5601 For air movement not to affect appliance see clause 5 3 1 Fo...

Страница 6: ...layout refer to figure 2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW Refe...

Страница 7: ...ting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the burner fails to ignite wait 20 seconds and repeat the ignition procedure Refer figure 8 To turn...

Страница 8: ...pplier or authorised service person listed in this manual Flame characteristics The heater flame should be stable no lifting from the burner and the logs should glow after approximately 15 minutes ope...

Страница 9: ...speed Controller Electronic direct spark Power requirement 240 VAC 10 A Power consumption 90 VA maximum Minimum cavity Height 605mm dimensions dimensions Width 700mm Depth 393mm Optional Accessories...

Страница 10: ...niture and curtains refer to warning on page 4 For minimum clearances refer figures 10 and 11 Note Ensure that the combustion air opening under the heater is not obstructed A CLEARANCE OF 50mm MUST BE...

Страница 11: ...m air vents are unobstructed If an exhaust fan or other heating appliances are present switch them on This is to test that there is no interaction between the Cannon heater and other appliances Refer...

Страница 12: ...12 Installation WITHOUT a flue connected 13 14...

Страница 13: ...n is to be carried out only by a qualified electrician 7 Remove the lower front cover by unscrewing two M5 screws from the air intake slot Refer figure 16 If unit is fitted with supply flexible cord e...

Страница 14: ...s in top clamp and remove side clamps Refer figure 21 Sealing 12 All gaps between heater case and fireplace are to be sealed Seal with foam tape around top and sides of heater flange as required Refer...

Страница 15: ...tion flanges should be hard against masonry Se cure case flanges to the masonry Refer figure 25 15 Connect incoming gas supply pipe to regulator For inlet position see figure 26 Close gate over gas su...

Страница 16: ...on the burner head ensuring that the charring faces the front Refer fig ure 28 b Place log No 2 onto the 2 left back pins Refer figure 29 c Place log No 3 on single right front pin ensure fork locate...

Страница 17: ...e point is closed with a captive screw Turn screw 6 revo lutions anticlockwise to open the pressure point as indicated on figure 34 a and place manometer tube over the test point as per figure 34 b Ga...

Страница 18: ...y clockwise Replace plastic cap Ensure the little lug is positioned towards lower right hand side to clear the control 28 Refit the lower front cover making sure not to damage the power cord 29 Follow...

Страница 19: ...sary Install a chimney plate and cowl to the chimney opening using weath erproof mortar to common building practice Remove any curved firewall that slopes too far forward to the fireplace opening as i...

Страница 20: ...s maxi mum until the flame has been established Terminal 14 white wire into the 8 way switch connector will be energised as soon as the flame has been sensed 5 Confirm spark is produced A blue spark c...

Страница 21: ...will go into lockout if the flame current sensitivity is less than 0 5 micro amps The approximate signal strength on high flame is about 10 micro amps and on low 4 micro amps The signal strength will...

Страница 22: ...nition device needs to be removed to allow re moval of the gas control Remove LH screw from front lower section of ignition device Remove screw from front of rectifier lead located below domed cap on...

Страница 23: ...nergise dependant on room temperature The burner should now operate on high setting To replace the fan pressure switch 1 Remove the lower fan cover by unscrewing two M5 screws through the air intake s...

Страница 24: ...appliance or spare parts contact the CANNON distributor Sampford IXL 52 70 Sparks Avenue Fairfield Vic 3078 Phone 1300 727 421 Fax 1300 727 425 email service sampfordixl com au Wiring diagram Data pl...