Installation
FUSE / BREAKER SPECIFICATIONS:
An over-current protection device (circuit breaker or fuse) must be used with this downrigger. Coast Guard require-
ments dictate that each ungrounded current-carrying conductor must be protected by a manually reset, trip-free
circuit breaker or fuse.
The following breaker size is a recommended guideline:
1 downrigger—30A @ 12 vdc
2 downriggers—60A @ 12 vdc
For additional information, please consult appropriate ABYC (American Boat and Yacht Council) and Coast Guard
requirements.
Reference:
United States Code of Federal Regulations: 33 CFR 183—Boats and Associated Equipment
ABYC E-11: AC and DC Electrical Systems on Boats
Powering Multiple Downriggers
When operating multiple Digi-Trolls, run a
maximum of 2 downriggers per dedicated battery
. The advanced
features of the Digi-Troll can keep the unit working virtually all the time. (See below for the recommended wiring
setup.)
Typical Operating Time*:
1 Digi-Troll per battery –
24 hours.
2 Digi-Trolls per battery –
10 hours.
*Time based on lab results using a 15lb weight and Deep-Cycle batteries. Actual run time will vary.
Red
( + )
Black ( – )
Connect Multiple
Batteries in Parallel