LP 4200 Surge Protector 

 
Why install an LP 4200 

Lightning strikes within 1-2 miles of your installation can create power surges or spikes, 

which may damage your unprotected Invisible Fence

®

 Brand pet containment system. 

The Surge Protector is designed to protect your Invisible Fence

®

 Brand pet containment 

system from surges or spikes that can reach it via your AC power connection and/or your 

buried Boundary Wire. 

 

Install the Surge Protector 
Plan the installation as directed by the Operating Guide: 

- Use only in dry, protected areas. 
- ICT 801 & 802 Systems, install the LP-4200.  

 

STOP

: CHECK THE OUTLET YOU PLAN TO 

USE BEFORE INSTALLING ANY INVISIBLE 

FENCE

®

 BRAND EQUIPMENT TO ENSURE 

THE OUTLET IS WORKING!! 

The LP-4200 Surge Protector must be plugged into a grounded (3-prong) outlet that is 
within 5 feet of the Fence Transmitter. ALWAYS use a grounded (3-prong) outlet to ensure 

maximum protection. Cutting or removing the 3rd prong from the Surge Protector or using 

a 2-prong to 3-prong outlet converter will render the protector ineffective against surges 

or spikes.  

 

If possible, DO NOT use an AC circuit protected with a GFCI (ground fault circuit 

interrupter). Both the Surge Protector and the Fence Transmitter will function properly, 
but in are cases, nearby lightning strikes may cause the GFCI to trip. Without power, your 

dog may be able to escape. You will have to reset the GFCI to restore power to the system. 

CAUTION

• To reduce the risk of electrical shock, disconnect power to the receptacle (outlet) before 

installing or removing the Surge Protector. When removing receptacle cover screw, cover 

may fall across plug pins or receptacle may become dislodged.  
• Use only with a duplex receptacle having a center screw. 
• Secure unit in place with screw included with Surge Protector. 

 

Step 1: Turn the power OFF to the outlet that the Surge Protector and Fence Transmitter 
will be plugged into. 

 

Содержание Invisible Fence ICT 801

Страница 1: ...1 Top Dog Kit ICT Transmitter and Installation Manual...

Страница 2: ...them an audible warning every time they get within about eight feet of the boundary wire If your pet fails to heed this warning they will receive a mild correction Through proper training your pet wi...

Страница 3: ...layout requires you to cross a driveway a circular saw or gas powered cut off saw mason blade and caulk gun will be needed Optional Tools NOTE will not apply to every installation Brooms 100 clear si...

Страница 4: ...usually the best location If you are not sure the intended outlet is grounded use a 3 wire circuit analyzer or contact an electrician Caution Never install a system or equipment or service any equipme...

Страница 5: ...hes deep You will run the wire through garden hose flex tubing or heavy wall PVC pipe in the trench and then bury it by hand The pipe will keep the wire from being cut or abraded by the stones particu...

Страница 6: ...One loop around the perimeter of the property with loops pinched in on sides All house exits are protected whoever dog cannot have access to both front and back yard at the same time Installation Dia...

Страница 7: ...res The mark out company will send a representative to identify underground utilities on your property and place colored flags to mark found utilities Wires that cross these areas MUST BE BURIED BY HA...

Страница 8: ...sually run on the most direct route from the signal field loop wire to the transmitter and is buried the same way as the loop wire Twisted pair is also used to connect an extension loop s to the prima...

Страница 9: ...TE this is where the physical perimeter wire will be buried not where your pet will stop 4 Remember to leave some excess slack where the twisted pair will connect to the perimeter boundary wire this w...

Страница 10: ...planned path for the perimeter boundary wire burying the wire around the yard keep in mind your pet will stop 6 8ft from where the wire is buried Leave some slack where there are large rocks rock wal...

Страница 11: ...eep water from settling in the pipe prop the middle up higher than the ends c After sealing the driveway with the appropriate driveway crossing or burying the wire in a gravel driveway use a broom to...

Страница 12: ...akes the loop around the property The picture below represents the two sides of the twisted pair each should be connected to the perimeter boundary wire using the included wire nuts and direct burial...

Страница 13: ...e Protector and backup battery must be installed in a dry protected indoor location near a constant source of 110vAC power outlet An area on the inside of an exterior wall in a basement garage or util...

Страница 14: ...ounded 3 prong outlet to ensure maximum protection Cutting or removing the 3rd prong from the Surge Protector or using a 2 prong to 3 prong outlet converter will render the protector ineffective again...

Страница 15: ...tive action and may also interfere with the operation of the fence transmitter Step 3 Locate the end of the twisted pair that you had run through the wall there should be enough slack to reach the loc...

Страница 16: ...tor hole Step 6 Insert the opposite stripped ends of the two transmitter wires Described on Page 17 Step 2 of ICT Transmitter Installation into the connectors for the appropriate loop on the ICT Trans...

Страница 17: ...nto the terminals for the appropriate loop on the ICT Transmitter Push in the plastic tabs and insert the wires one into each port Let go of the tabs once the wires have been pushed up in the port and...

Страница 18: ...CT 801 Transmitter Installations The ICT 801 is a single loop programmable transmitter designed for installations with up to 3 000 feet of signal field wire and up to 150 feet of twisted pair wire The...

Страница 19: ...n the signal has reached maximum output level which is caused by excessive loop size excessive resistance or poor connections Battery Fault When lit indicates that the 12VDC backup battery is either n...

Страница 20: ...l blinking the settings will not be saved to system memory Audible Alarm There is an audible alarm for certain alert conditions See table below Press and release either the S1 or the S2 button on the...

Страница 21: ...ignal field width 1 Hold the Invisible Fence Brand Computer Collar unit so it is parallel to the signal field wire 2 Hold the collar so it is about the same height and at the same angle as it will be...

Страница 22: ...Reminder Always make sure to test your Computer Collar unit to make sure it is set to the same operating frequency as the system s transmitter If your collar is not operating at the perimeter boundary...

Страница 23: ...s coat weight and age change The pet s coat may change from season to season IMPORTANT Allow the pet to become accustomed to its new Invisible Fence Brand Computer Collar unit The collar should be re...

Страница 24: ...of the Computer Cap unit s battery chamber Wait 5 minutes before inserting your new Power Cap 5 Line up the lugs on each side of the bottom of the new Power Cap unit with the grooves in the sides of...

Страница 25: ...denial of a warranty claim The use of unnecessary force may damage the case and render the Power Cap unit inoperable NEVER open a Power Cap unit dispose of it in a fire recharge it heat it above 212 F...

Страница 26: ...Unit not responding to signal field loop wire Power Cap Battery in the Computer Collar Unit is dead or weak Signalfieldwire has a break Power is not supplied to the transmitter or power is out Replace...

Страница 27: ...160 mAh capacity Replace only with equivalent Power Cap Battery that can be obtained from your Invisible Fence Brand Dealer The Transmitter operates on one 1 Valve Regulated Lead Acid Battery with a 1...

Отзывы: