The recommendations contained in this section are designed to assist you in reducing false alarms. The first column contains the
Command Locations and Digit Positions in parentheses ( ). The second column is the recommended program option followed by a
brief explanation.
Program Option
CL
Program Function
Comments
Arming/Combination
09 (2)
Combination
This feature is enabled to prevent unauthorized users from
Options
Command
activating certain keypad functions. When activated, this
command will require a valid User Combination to perform
such functions as Bypassing a Zone, Group Bypassing, Key-
pad Activated RPS, Central Station and Bell Testing, and
Instant Arming. For additional assistance with commands
requiring User Combinations, see page 24 (Command Sum-
mary).
Arming/Combination
09 (4)
Chirp Alert
This option minimizes the possibility of leaving the system
Options
unarmed (faulted) when exiting. The system is armed in the
normal manner and the user exits through the delayed exit
door. If the door does not close properly, returning the loop
to the normal state, the system will transition from the Exit
Delay to the Entrance Delay at the completion of the Exit
Delay time and chirp the Bell, alerting the user to the error in
arming the system.
Loop Control
1F - 26 &
Loop Response
This option determines the response time of the loop itself.
49 - 50 (2)
Time
It acts as a buffer on the loop to minimize the possibility of
fast acting sensors, such as swingers or window foil, produc-
ing false alarms.
Loop Control
1F - 26 &
Loop Restore Type This option is used in conjunction with CL 17 - 1E & 40 - 47
49 - 50 (3)
Digit Positions (3 & 4), Restore Reporting Code, and CL 2A
(2), Restore Receiver Select. The panel can be programmed
to send a Restoral Report only when the loop is normal and
the system is disarmed. With this arrangement, any loop
which is triggered multiple times while armed will only send
one alarm report until the system is disarmed. This prevents
the system from tying up the phone line with continuous alarm
and restoral reports.
Loop Control
1F - 26 &
Loop Arming Type
There may be occasions where it is desirable to program all
49 - 50 (4)
doors and interior points as delayed. Or you may need to
program interior zones to be delayed only during the Entry/
Exit Delay Time. This Command Location allows a variety of
Arming Types to help minimize false alarms.
Event Reporting
2A (5 & 6)
Cancel Report
This feature should always be enabled on reporting systems,
Code/Cancel
especially if the system does not send Opening and Closing
Report Receiver
Reports. A Cancel Report is sent to the monitoring station in
Select
the event that an Authorized User clears the alarm while the
bell is still active. The Cancel Report Code (Digit Position 5) is
actually a two-digit code with the first digit being programmed
by the installer and the second digit being the User ID # when
the report is sent. Digit Position (6) determines which receiver
gets the Cancel Report.
RECOMMENDATIONS FOR REDUCING FALSE ALARMS