23
Figure 28: TRI File in the text editor
The column position of the 26 metadata is fixed in each row. For example, the Can
ID
of the
respective
sensor
is always in the second column.
Table 1 shows the column positions, the label, and the purpose and specifics of the metadata. The
values marked in
blue
are only visible in
enhanced mode
in
Table 1: TRI Metadata
column
position
Designation
Purpose and particularities
1
Header
bus header for OBD/UDS (hexadecimal) 0 = no protocol
or specific Can Bus Identifier for protocol
2
Can ID
Can Bus Identifier (hexadecimal)
when using OBD/UDS/TP2.0: Address for querying the device
3
Format
0 -> Big endian; 1-> little endian; 2 -> VEMS (seriell);
4 -> IEEE-754 float (lenght=4)
4
Start byte
First byte in Can Bus packet (0-7)
5
Length
Length in bytes - 1, 2 or 4
for AINs: Attenuation strength 0-249 (0 = no attenuation)
6
unsigned
if the value is negative, please do not tick the box
7
shift Bit
moves the bit within the value to the right by position X
8
CAN Mask
Masks the value before shift (0 -> no mask applied)
9
Decimal places
Number of decimal places
10
Sensor Name
Sensor
name (maximum 15 characters, no special characters)
11
initCalc
Can Bus value is multiplied by this number
Result=((Can Bus value & MASK)>>SHIFT)*IINITOFFSET
12
initOffset
after multiplication this value is added
13
Multiplex /
Mappertype
OFF; Multiplex ON; MAP (linear analog sensors); NTC (3 constants
and pull-up resistor (Steinhart-Hart))
14
start bit /
MapperInfo1
Multiplex start bit /
Varies by mapper type
15
bit length /
MapperInfo2
Multiplex bit length /
Varies by mapper type
16
Multiplexer /
MapperInfo3
Multiplexer/
Varies by mapper type
17
Multiply /
MapperInfo4
Global multiplication factor for sensor (default 1) / Varies by mapper
type
18
AIN active
Internal analog sensor only; enables input pin polling
19
Min
Lower warning value
20
Max
Upper warning value
21
RefSensor
reference sensor; only if the RefValue for this
sensor
is exceeded,
warning is active
22
RefValue
Reference value for enabling the alert
24
Pop
Popup active when exceeding or falling below the warning value
25
Blink
LED active when exceeding or falling below the warning value
26
Sensor type
Used for units calculation: 0=none; 1=pressure; 2=temperature;
3=speed; 4=combustion ratio