Figure 30: Popup to edit the sensor in normal mode
In addition to the
min
and
max
warning values, you can also assign/change the names of your
sensors (maximum 15 characters
–
no special characters)
and switch popups for the
warning values
on and off. After you have changed/renamed the sensor, you have to confirm the changes with the
Apply button
. Once you have adjusted all
sensors
according to your wishes, you can save the changes
locally to your computer via the
safe
to
file
button on the button and later upload them to your
data display via WLAN via the
upload section
in the
oDSS
.
8.2.2
enhanced mode
If you switch on the
enhanced mode
, you get even more possibilities to configure your sensors and
the associated Can Bus details and reference sensors.
With the reference sensor, you can set the min or max warning even better. For example, if you set a
min warning of 1.1 bar for the oil pressure, you will constantly get a pop-up even when idling. If you
now specify the sensor speed as
RefSensor
with a
RefValue
of 3000, the min oil pressure warning
will only be activated if the oil pressure is less than 1.5 bar, but only as long as the
sensor
speed has a
value above 3000.
Figure 31: Popup for editing the sensor in enhanced mode