29
INSTALLATION
– MAINTENANCE – ADJUSTMENTS
The information and operations illustrated in this section are dedicated exclusively to fitters.
The installation and all adjustments, transformations and maintenance operations shown in this section must be carried
out exclusively by qualified personnel, in observance of local legislation
(Law no. 46/90 and DPR 447)
.
If in doubt, contact Technical Assistance.
Incorrect installation or adjustment may cause damages to people, animals or things. The manufacturer declines all
responsibility for installation or adjustment which do not comply with the instructions given in this section.
Installation must conform to
UNI 7131
(the lastest revision).
Inserting and fastening the appliance
Remove the appliance from the packaging, ensuring that it is complete and undamaged. If in doubt, do not proceed and contact
the dealer of Technical Assistance immediately.
Remove the protective plastic.
The material of items adjacent to the appliance (furniture( must resist temperature surges of at least 65 K (90°C with a ro om
temperature of 25 °C).
Also observe the critical distances from the adjacent walls/furniture.
Critical distances (X and Y) are the same for all models. See figure 3 below.
N.B.: In figure 3, the side of the furniture is shown to the left of the appliance. If you wish to install it on the right, observe the same
critical distances indicated in the table (Y).
Make sure that the distance between the pan stand of the appliance and any furniture of hoods above the appliance is at least 650
mm.
Any lateral work surfaces within critical distance Y must remain below the height of the appliance surface.
X : 55mm
Y: 100mm
Figure 3
The appliance must be fastened to the unit using the screws supplied with it.
Fasten the 2 posts to the hob through the appropriate holes with the screws supplied (screw and nut). Then fasten the posts in the
position required using the screws.
The appliance is now fastened to the unit. For any maintenance requiring the dismantling of the appliance from the unit, simply
loosen the 2 screws.
Gas connection
Before connecting the gas supply, make sure that the local distribution conditions (type and pressure of gas) and the adjustment of
the appliance are compatible. The appliance adjustment conditions are indicated on the data plate on the underside.
The appliance input consists of a gas ramp with the end facing sideways, to simplify installation.
The end is cylindrical,
8 mm diameter
, unthreaded, for at least 30 mm. Where permitted by the installation standards in force,
connection to the gas main may take place using a flexi-pipe with a gas-proof press fitting (complete with ogive).
In the specific case of built-in installation, UNI 7131 forbids direct connection of the appliance to the gas bottle by flexi-pipe. It is
therefore necessary to connect the appliance to a fixed system (UNI 7129), which will be connected to the gas bottle and the
appliance by flexi-pipes (UNI 7140) with a rubber insert support and relative clamps (UNI 7141). The flexi-pipe must have a
maximum length of 1.5 m, without intermediate joints, and must not run through two different rooms.
The connections must not
cause the pipe to twist, bend or be crushed and the pipe must not come into contact with sharp items or edges and must not
exceed a temperature of 50°C. The flexi-pipe and relative rubber insert support must be open to inspection.