WARRANTY 

GENERAL 

Camus Hydronics Limited (“Camus”), extends the following LIMITED WARRANTY to the owner of this appliance, 
provided that the product has been installed and operated in accordance with the Installation Manual provided with 
the equipment. Camus will furnish a replacement for, or at Camus option repair, any part that within the period 
specified below, shall fail in normal use and service at its original installation location due to any defect in 
workmanship, material or design. The repaired or replacement part will be warranted for only the unexpired portion of 
the original warranty. This warranty does not cover failures or malfunctions resulting from: (1) Failure to properly 
install, operate or maintain the equipment in accordance with Camus’ manual; (2) Abuse, alteration, accident, fire, 
flood, foundation problems and the like; (3) Sediment or lime buildup, freezing, or other conditions causing 
inadequate water circulation; (4) Pitting and erosion caused by high water velocity; (5) Failure of connected systems 
devices, such as pump or controller; (6) Use of non-factory authorized accessories or other components in 
conjunction with the system; (7) failing to eliminate air from, or replenish water in, the connected water system; (8) 
Chemical contamination of combustion air or use of chemical additives to water. 

HEAT EXCHANGER 

If within TEN years after initial installation of the appliance, a heat exchanger, shall prove upon examination by 
Camus to be defective in material or workmanship, Camus will exchange or repair such part or portion on the 
following pro rated limited warranty. (1) Years one through five - standard warranty (2) Years six through ten - 
replacement purchase price pro rated at the following schedule: Year six - 60%, Year seven - 65%, Year eight -70%, 
Year nine -75% Year ten -80% of the current list price of the current list price This term is reduced to FIVE years if the 
appliance is used for other than hydronic space heating. 
Heat Exchanger shall be warranted for (20) years from date of installation against “Thermal Shock” (excluded, 
however, if caused by appliance operation at large changes exceeding 150 ºF between the water temperature at 
intake and appliance temperature, or operating at appliance temperatures exceeding 230 ºF). 
 

BURNER 

If within FIVE years after initial installation of the appliance a burner shall prove upon examination by Camus to be 
defective in material or workmanship, Camus will exchange or repair such part or portion. 
 

ANY OTHER PART 

If any other part fails within one (1) year after installation, or eighteen (18) months from date of factory shipment 
based on Camus' records, whichever comes first. Camus will furnish a replacement or repair that part. Replacement 
parts will be shipped f.o.b. our factory. 
  

HOW TO MAKE A CLAIM 

Any claim under this warranty shall be made directly to Camus Hydronics Limited Canadian Head Office 
 

SERVICE LABOR RESPONSIBILITY 

Camus shall not be responsible for any labour expenses to service, repair or replace the components supplied. Such 
costs are the responsibility of the owner. 
 

DISCLAIMERS 

Camus shall not be responsible for any water damage. Provisions should be made that in the event of a 
water/appliance or fitting leak, the resulting flow of water will not cause damage to its surroundings. 

 

 
Name of Owner 

 

 
Name of Dealer 

 

 
Address 

 

 
Address 

 

 
 

 

 

 

 
Model No. 

 

 
Serial No. 

 

 
Date of Installation: 

 

 
Date of Initial Operation: 

 

6226 Netherhart Road, Mississauga, Ontario, L5T 1B7, CANADA

Содержание MICOFLAME 2 Series

Страница 1: ...r appliance WHAT TO DO IF YOU SMELL GAS o Do not try to light any appliance o Do not touch any electrical switch do not use any phone in your building o Immediately call your gas supplier from a neigh...

Страница 2: ...8 RELIEF VALVE 10 9 FREEZE PROTECTION 10 10 WARNING REGARDING CHILLED WATER SYSTEMS 11 11 PIPING OF SYSTEM TO BOILER FIG 4 11 12 PLACING BOILER IN OPERATION 13 13 IGNITION SYSTEM SAFETY SHUT OFF DEVI...

Страница 3: ...ty having jurisdiction the installation must conform to the Standard for Controls and Safety Devices for Automatically Fired Boilers ANSI ASME CSD 1 The qualified installer shall instruct the end user...

Страница 4: ...installed above the level of the building s radiation system a low water cutoff device must be installed in the boiler outlet at the time of installation Some local codes require the installation of a...

Страница 5: ...tion leading to reversal of the natural draft action of the venting system Under these circumstances an engineered air supply is necessary If the heater is to be installed near a corrosive or potentia...

Страница 6: ...fans must be running in order for the appliance to proceed to trial for ignition MicoFlame series 2 is supplied with more than one burner may use burners that are not of identical size in order to acc...

Страница 7: ...to operate at inlet gas pressures not exceeding PSI 14 W C If higher pressures are present consult the gas company for correction When pressure testing the gas supply piping at pressures above PSI th...

Страница 8: ...upported approximately every 4 feet to prevent sagging and maintain a minimum upward slope of per foot from the boiler to the vent terminal When an existing boiler is removed from a common venting sys...

Страница 9: ...structions from the chimney and flue which might impede draft action Replace any damaged or deteriorated parts of the venting system A qualified service technician should follow this procedure when in...

Страница 10: ...efficient and is considered to be a category II or IV appliance Three venting options are available for this boiler in both condensing and non condensing configurations See Figure 2 for details Pleas...

Страница 11: ...ACNA AFTS 100 73 Standard When venting through unheated spaces with single wall vent insulation should be wrapped around the vent pipe to prevent flue gas condensation inside the vent Periodically che...

Страница 12: ...inst damage that could be caused by malfunctioning controls or excessive water pressure If a relief valve is not used warranty is void The relief valve is to be located as near as practical to the out...

Страница 13: ...tic means to prevent gravity circulation of chilled water through the boiler Chilled water in the boiler will create condensate on the boiler tubes which will collect in the combustion chamber causing...

Страница 14: ...radiation level it must be provided with a low water cutoff device at the time of boiler installation Available from factory A pressure relief valve is supplied with each MicoFlame series 2 boiler Th...

Страница 15: ...ance filled with air Start up boiler following instructions provided Operate entire system including pumps and radiation for at least 1 hour Check water level in expansion tank If level exceeds of tan...

Страница 16: ...he inlet temperature is greater than 110 F but not greater than 140 F no further adjustment is required e Check the inlet temperature after 5 minutes and make final adjustments 15 INSTANTANEOUS WATER...

Страница 17: ...t burner every six months for proper flame characteristics 16 1 MAIN BURNER The main burner figure 7 should display the following characteristics Acceptable CO and CO2 levels for complete combustion L...

Страница 18: ...1 6 1 9 1 6 1 9 1 2 1 6 1 2 1 6 2000 1 9 2 2 1 9 2 2 1 5 1 9 1 5 1 9 Depending on field conditions air box pressures will have to be adjusted accordingly Always set the appliance for a CO2 level in th...

Страница 19: ...e electrode does not appear overheated or fouled with carbon It may be necessary to clean the ignition electrode using steel wool Once the pilot appears to be properly set reinstall it into the applia...

Страница 20: ...ction 15 of this manual After the first season of operation inspect the heat exchanger and venting Follow the detailed instructions in section 6 of this manual CAUTION Label all wires prior to disconn...

Страница 21: ...If pilot fails to light and you suspect air in the line close the main manual valve and repeat lighting steps 1 thru 5 7 Once the pilot lights it should envelope the ignition rod and ground electrode...

Страница 22: ...und electrodes are positioned properly Clean with steel wool if necessary Verify that back of burner box is fully engaged into the retaining slot in the combustion chamber base 5 Pilot lights but main...

Страница 23: ...ICAL DIAGRAMS Each MicoFlame series 2 boiler will be provided with its own wiring diagram to guarantee that any options ordered with the unit are properly detailed The following diagram 99 5072 and 99...

Страница 24: ...22...

Страница 25: ...23...

Страница 26: ...24 22 EXPLODED VIEW...

Страница 27: ...25 23 MICO FLAME REPLACEMENT PARTS LIST...

Страница 28: ...standard warranty 2 Years six through ten replacement purchase price pro rated at the following schedule Year six 60 Year seven 65 Year eight 70 Year nine 75 Year ten 80 of the current list price of t...

Страница 29: ...t water heaters and heating boilers as well as a into every single unit For more information supplier of specialty HVAC products Our service line is open 24 hours 7 days a week on our innovative produ...

Отзывы: