HSEUiREG07201(R2) MANUAL

                 

Camtec Power Supplies GmbH  -  Gewerbestrasse 30  -  DE-76327  Pfinztal / Germany   

P.4/15 (03/2017.02.2) 

Tel. +49 (721) 46596 - 0  Fax +49 (721) 46596 - 77    

www.camtec-gmbh.com

   -   

[email protected]

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death) 

 

Technical Data Table

 

AC Input Range 

90-132Vac, 184-264Vac (115/230Vac input selector, factory setting is 230Vac) 

AC Input Frequency 

47-63Hz 

DC Input Range 

250-375Vdc (input selector set to 230Vac) 

AC Input Rated  

115Vac < 12,7A, 230Vac <7,2A 

DC Input Rated 

250Vdc <3,6A  375Vdc <2,4A 

DC Voltage programmable 

0 - 18Vdc 

0 - 30Vdc 

0 - 50Vdc 

0 - 60Vdc 

0 - 90Vdc 

0 - 130Vdc  0 - 180Vdc  0 - 240Vdc 

DC Current programmable 

0 - 40A 

0 - 30A 

0 - 18A 

0 - 15A 

0 - 10A 

0 - 7A 

0 - 5A 

0 - 3,8A 

Over Voltage Protection 

22Vdc 

35Vdc 

59Vdc 

70Vdc 

105Vdc 

150Vdc 

210Vdc 

280Vdc 

Over Current Protection 

44A 

33A 

19,8A 

16,5A 

11A 

7,7A 

5,5A 

4,2A 

Ripple Noise 230Vac 20MHz  40mVpp 

40mVpp 

100mVpp 

120mVpp 

150mVpp 

200mVpp 

300mVpp 

400mVpp 

Load Regulation 0-100% 

< ±0,05%  

< ±0,05%  

< ±0,05%  

< ±0,05%  

< ±0,05%  

< ±0,05%  

< ±0,05%  

< ±0,05%  

Power Maximum 

720W, 90-132Vac, 184-264Vac 

Cooling 

Natural convection 

Efficiency 

Up to 90% 230Vac at full load  

Short Circuit Resistance 

yes 

Open Circuit Protected 

yes 

Base Load (OCP) 

Non required (open circuit protected) 

Load Regulation Time 

<1ms on load switch 10-100% 

Accuracy 

Ureg: 

 ± 0,5%, Ireg: 

 ± 1,5%, Umon: 

 ± 0,5%, Imon: 

 ± 1,5%, Uref: 

 ±1,0% 

Temperature Control 

yes, thermal shutdown & autorecovery (+60°C, outside measuring point distance 50mm) 

Hold Up Time 

>40ms 230Vac

 

mains buffering at full load 

Inrush Current 

<9,8Arms <13,8Apeak 230Vac active electronic inrush protection (no simple NTC) 

MCB (Circuit Breaker) 

16A curve B @ 230Vac / 25A curve B @ 115Vac 

Start-up Delay 

Typ. 420ms @ 230Vac, 590ms @ 115Vac 

Softstart 

Typ. 100ms 

Start-up from Shutdown 

Typ. 330ms 

Ambient Temperature 

- 20°C…+60°C operating, derating 2,5%/°C >50°C 

Storage Temperature 

- 40°C…+85°C 

Ambient Conditions 

Humidity 95% non-condensing @ 25°C, climate class 3K3, pollution degree 2 

ROHS 

2011/65/EU, (EU)2015/863 

REACH 

EG No. 1907/2006 

EMI 

EN55032 class B, EN61000-6-3 

EMS 

EN61000-6-2 

Safety 

EN61010-1, EN61010-2-201, EN62368-1, EN60950-1, EN60204-1 

Protection Class I 

PE connection required 

Isolation Input to Output 

3000Vac 

Isolation Input to Case 

2500Vac 

Isolation Output to Case 

500Vdc, 

60Vdc 2500Vdc 

MTBF (IEC61709) 

400000h (Meantime Between Failures: statistic time between failures after repairs) 

MTTF (IEC61709) 

147212h (Meantime To Failure: statistic time to ever fails) 

Dimensions (HxWxD) 

130x200x115mm 

Weight 

3,1kg / 6,8lbs 

AC Terminals  

Input Screw Terminal 3x 0,5 – 16mm² AWG26 – AWG6 (L,N,PE), technical data see “connections” 

DC Terminals 

Output Screw Terminal 4x 0,5 – 16mm²  AWG26 – AWG6 (+ + / - - ), technical data see “connections” 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание HSEUiREG07201.060

Страница 1: ...ring Reference voltage f autonomous programming Remote Shutdown Sense control 2V per load line Power Good Relay DC ok Quick down programming option PS Precise dynamics on load change Series parallel o...

Страница 2: ...sembled device pass stress aging to achieve an even level and to prevent from delayed failures Our internal product engineering guidelines provide a clear target Camtec product reputation must say mou...

Страница 3: ...It is the exact and real value at the output terminals The latency signal preset to the measured value is negligible since the control circuit is constructed completely analogously Constant Voltage or...

Страница 4: ...ed yes Base Load OCP Non required open circuit protected Load Regulation Time 1ms on load switch 10 100 Accuracy Ureg 0 5 Ireg 1 5 Umon 0 5 Imon 1 5 Uref 1 0 Temperature Control yes thermal shutdown a...

Страница 5: ...2 Ureg Input 3 Ireg Input Current Programming Select 0 5V 0 10V 0 20mA 4 20mA 1 M working resistance with Vprog 500 working resistance with Iprog 4 Ireg Input 5 Umon Output Voltage Monitor Select 0 5...

Страница 6: ...bh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death Monitor Outputs Moni...

Страница 7: ...desired set point may be very long The power supply has large built in capacitors and an enormous energy reserve A similar effect occurs by skidding input energy which is not easily removed from the p...

Страница 8: ...nes can cause damages to the power supply unit External Shutdown SD The power supply is set to the Shutdown mode when the control input is either shorted via a relay contact a switch contact or an NPN...

Страница 9: ...W HSEUiREG07201 240 240Vdc 3 0A 190Vdc 3 8A 720 722W Inrush Current Protection electronic The power supply unit has an electronic current limiter 230Vac 9 8Arms 13 8Apeak It is a precisely working cir...

Страница 10: ...ors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section Up to 5 pcs HSEUiREG can be paralleled The HS...

Страница 11: ...ncrease The following formula shows dv dt i C When an electronic current sink is used the output voltage remains constant at the set value The current sink provides a quick dynamic response Fig 1 Fig...

Страница 12: ...n a failure or malfunction could result in injury or death Mechanics ST HD Baseplate Cooling Temperature Management The temperature management of the HSEUiREG series provides a direct dissipation of t...

Страница 13: ...ired and for active devices 15mm space from the sidewalls For proper air convection it is necessary to install the HSEUiREG One can use the DIN Rail installation equiped standard with our patented 35m...

Страница 14: ...5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 20 12mm H6 0 20 SW 14mm 10 0mm H10 0 12 12mm H10 0 22 EB 15mm The length of ferrules is to be chosen depending on the...

Страница 15: ...tion outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to persons or thing...

Отзывы: