background image

 

 

   

HSEUiREG07201(R2) MANUAL

                 

Camtec Power Supplies GmbH  -  Gewerbestrasse 30  -  DE-76327  Pfinztal / Germany   

P.14/15 (03/2017.02.2) 

Tel. +49 (721) 46596 - 0  Fax +49 (721) 46596 - 77    

www.camtec-gmbh.com

   -   

[email protected]

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death) 

 

Connections

 

Clamping Yoke Connector Specifications

 

 

Input / Output connections 

Signal connections plugs 

Tightening torque min. – max. 

1,2 – 2,2Nm (blade 1,0x5,5 DIN5264 ) 

0,2 – 0,25Nm (blade 0,4x2,2 DIN5264) 

Touch-safe protection acc. to DIN VDE 0470 

IP20 plugged/ IP10 unplugged 

Not applicable 

Clamping range, min. – max. 

0,5 – 16mm² / AWG26 – AWG6 

0,2 – 1,5mm² / AWG28 – AWG14 

Solid, H05(07) V-U min. – max. 

0,5 – 16mm² 

0,2 – 1,5mm² 

Stranded, H05(07) V-U min. – max. 

6 – 16mm² 

0,2 – 1,5mm² 

Flexible, H05(07) V-U min. – max. 

0,5 – 16mm² 

0,2 – 1,5mm² 

w. plastic collar ferrule, DIN 46228 pt 4 min. – max. 

2,5 – 10mm² 

0,2 – 1,5mm² 

w. wire end ferrule, DIN 46228 pt 1, min. – max. 

2,5 – 10mm² 

0,2 – 1,5mm² 

Plug gauge in accordance with EN 60999 a x b; ø 

5,4 x 5,1mm; 5,3mm 

2,4 x 1,5mm; 2,3mm 

Pitch (P) 

10,16mm 

3,5mm 

Wire Stripping Length (fine wired)

 

Nominal Cross Section 

Wire End Ferrule 

Stripping Length 

Wire End Ferrule 

Stripping Length 

0,25mm² 

H0,25/5 

5mm 

H0,25/10 HBL 

8mm 

0,5mm² 

H0,5/6 

6mm 

H0,5/12 OR 

8mm 

1,0mm² 

H1,0/6 

6mm 

H1,0/12 GE 

8mm 

2,5mm² 

H2,5/12  

12mm 

H2,5/19D BL  

14mm 

4,0mm² 

H4,0/12 

12mm 

H4,0/20 GDR 

14mm 

6,0mm² 

H6,0/20 

12mm 

H6,0/20 SW 

14mm 

10,0mm² 

H10,0/12 

12mm 

H10,0/22 EB 

15mm 

The length of ferrules is to be chosen depending on the rated voltage. The outside diameter of the plastic collar should not be larger than 
the pitch (P) 

 
 

Ordering Information 

Ordering Codes

 

Product Code 

Information 

Article Number 

HSEUiREG07201.018(R2) 

0-18Vdc 

3041084001CA 

HSEUiREG07201.030(R2) 

0-30Vdc 

3041084002CA

 

HSEUiREG07201.050(R2) 

0-50Vdc 

3041084003CA

 

HSEUiREG07201.060(R2) 

0-60Vdc 

3041084021CA 

HSEUiREG07201.090(R2) 

0-90Vdc 

3041084004CA

 

HSEUiREG07201.130(R2) 

0-130Vdc 

3041084005CA

 

HSEUiREG07201.180(R2)

 

0-180Vdc 

3041084006CA

 

HSEUiREG07201.240(R2)

 

0-240Vdc 

3041084007CA

 

HSEUiREG07201.018PS(R2)  PowerSink / Quick Downward Programming 

3041084011CA 

HSEUiREG07201.030PS(R2)  PowerSink / Quick Downward Programming

 

3041084012CA

 

HSEUiREG07201.050PS(R2)  PowerSink / Quick Downward Programming

 

3041084013CA

 

HSEUiREG07201.060PS(R2)  PowerSink / Quick Downward Programming

 

3041084031CA

 

HSEUiREG07201.090PS(R2)  PowerSink / Quick Downward Programming

 

3041084014CA

 

HSEUiREG07201.130PS(R2)  PowerSink / Quick Downward Programming

 

3041084015CA

 

HSEUiREG07201.180PS(R2)

 

PowerSink / Quick Downward Programming

 

3041084016CA

 

HSEUiREG07201.240PS(R2)

 

PowerSink / Quick Downward Programming

 

3041084017CA

 

Certificate Calibration 

Separate works certificate manufacturer calibration 

Back Plate Kit 

Hart mount plate kit including screws 

2201002001CA 

UI.DRIVE INTERFACE 

USB2.0 Interface & software download 

3041093001CA 

 

 
 
 
 
 
 
 

Содержание HSEUiREG07201.060

Страница 1: ...ring Reference voltage f autonomous programming Remote Shutdown Sense control 2V per load line Power Good Relay DC ok Quick down programming option PS Precise dynamics on load change Series parallel o...

Страница 2: ...sembled device pass stress aging to achieve an even level and to prevent from delayed failures Our internal product engineering guidelines provide a clear target Camtec product reputation must say mou...

Страница 3: ...It is the exact and real value at the output terminals The latency signal preset to the measured value is negligible since the control circuit is constructed completely analogously Constant Voltage or...

Страница 4: ...ed yes Base Load OCP Non required open circuit protected Load Regulation Time 1ms on load switch 10 100 Accuracy Ureg 0 5 Ireg 1 5 Umon 0 5 Imon 1 5 Uref 1 0 Temperature Control yes thermal shutdown a...

Страница 5: ...2 Ureg Input 3 Ireg Input Current Programming Select 0 5V 0 10V 0 20mA 4 20mA 1 M working resistance with Vprog 500 working resistance with Iprog 4 Ireg Input 5 Umon Output Voltage Monitor Select 0 5...

Страница 6: ...bh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death Monitor Outputs Moni...

Страница 7: ...desired set point may be very long The power supply has large built in capacitors and an enormous energy reserve A similar effect occurs by skidding input energy which is not easily removed from the p...

Страница 8: ...nes can cause damages to the power supply unit External Shutdown SD The power supply is set to the Shutdown mode when the control input is either shorted via a relay contact a switch contact or an NPN...

Страница 9: ...W HSEUiREG07201 240 240Vdc 3 0A 190Vdc 3 8A 720 722W Inrush Current Protection electronic The power supply unit has an electronic current limiter 230Vac 9 8Arms 13 8Apeak It is a precisely working cir...

Страница 10: ...ors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section Up to 5 pcs HSEUiREG can be paralleled The HS...

Страница 11: ...ncrease The following formula shows dv dt i C When an electronic current sink is used the output voltage remains constant at the set value The current sink provides a quick dynamic response Fig 1 Fig...

Страница 12: ...n a failure or malfunction could result in injury or death Mechanics ST HD Baseplate Cooling Temperature Management The temperature management of the HSEUiREG series provides a direct dissipation of t...

Страница 13: ...ired and for active devices 15mm space from the sidewalls For proper air convection it is necessary to install the HSEUiREG One can use the DIN Rail installation equiped standard with our patented 35m...

Страница 14: ...5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 20 12mm H6 0 20 SW 14mm 10 0mm H10 0 12 12mm H10 0 22 EB 15mm The length of ferrules is to be chosen depending on the...

Страница 15: ...tion outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to persons or thing...

Отзывы: