Programming/Monitoring V/C Analog Interface (Ureg /Ireg) (Umon/Imon)

 

The standard programming of the HSEUiREG Series is an analog interface. The output voltage is linearly 
proportional to the adjusted analog control signal. If the control signal 0V and/or 0A applies the power supply 
delivers 0V at the output. The power supply is already working from 0V output voltage and low load with high 
precision. 
 
The monitor signal is analog linear to the output voltage. The monitor signal for current and voltage is the real 
value that is measured directly at the output of the power supply. If a sense line is connected to compensate for 
the voltage drop across the load lines, the monitor signal is exactly the value that is measured at the connection 
point of the sense line. The description of the power supply in the sense operation is carried out in a separate 
section. 
 
The analog inputs and outputs are non-floating. The mass is connected to the DC negative output. 
 
The adapter provides the ability to select the desired input / output via a DIP switch. The burden of the control 
voltages is 1M

Ω

. The burden of the current interface is 500

Ω

. The latency to full compensation of V/C on the 

interface from 0-100% is 15ms for all HSEUiREG models. 
 
If the power supply is operated with a low load, the down-programming time up to the desired set point may be 
very long. The power supply has large built-in capacitors and an enormous energy reserve. A similar effect 
occurs by skidding input energy, which is not easily removed from the power supply. A PowerSink (PS) modul 
can be ordered as an option for each HSEUiREG power supply unit. The PS option is used for fast down 
programming and the degradation of skidding energy fed. The option must be equipped in the factory. 
 
 

For further information about the PS option, please refer to the technical details in a section PS-option. 
 

 

Compensation of Load Line Drop Voltage (Sense +/-), standard operation mode 

The HSEUiREG power supply has a Sense Mode to compensate for the voltage drop over long load lines. The 
compensation amounts to a maximum of 2V per load line. Under certain circumstances, it can be expected to 
apply more complicated external interference suppression. If sense is not used, Sense + and Sense - shall 
necessarily be connected by short bridges to AUX + and AUX - (factory setup). Make sure that +/- connections 
are matching! 

WARNING!

 Reverse polarity of the sense lines can cause damages to the power supply unit. 

 
Sense operation: Remove the bridges between Sense +, Sense -. Connect the sense lines directly to the load. 
Pay attention to the polarity of plus and minus of the load to prevent damage to the power supply. To avoid 
interference, twist the sense lines. To reduce inductive effects, we recommend that the load lines position is 
close to each other. To supply a pulsating load, the use of an electrolytic capacitor and a cermic capacitor has 
proved. The internal Over Voltage Protection (OVP) of the power supply controls the DC power directly to the 
DC output terminals. In case of an error the OVP acts automatically (see OVP values corresponding table).  
 
The sense terminals are directly connected to the power outputs. 
 
                               

Lokal Sensing

                                                                                   

Remote Sensing

 

                               (factory setup)                                                                                    (twisted sense lines) 
 
 
 
 
 

 
 
 
 

Содержание HSEUiREG07201.060

Страница 1: ...ring Reference voltage f autonomous programming Remote Shutdown Sense control 2V per load line Power Good Relay DC ok Quick down programming option PS Precise dynamics on load change Series parallel o...

Страница 2: ...sembled device pass stress aging to achieve an even level and to prevent from delayed failures Our internal product engineering guidelines provide a clear target Camtec product reputation must say mou...

Страница 3: ...It is the exact and real value at the output terminals The latency signal preset to the measured value is negligible since the control circuit is constructed completely analogously Constant Voltage or...

Страница 4: ...ed yes Base Load OCP Non required open circuit protected Load Regulation Time 1ms on load switch 10 100 Accuracy Ureg 0 5 Ireg 1 5 Umon 0 5 Imon 1 5 Uref 1 0 Temperature Control yes thermal shutdown a...

Страница 5: ...2 Ureg Input 3 Ireg Input Current Programming Select 0 5V 0 10V 0 20mA 4 20mA 1 M working resistance with Vprog 500 working resistance with Iprog 4 Ireg Input 5 Umon Output Voltage Monitor Select 0 5...

Страница 6: ...bh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death Monitor Outputs Moni...

Страница 7: ...desired set point may be very long The power supply has large built in capacitors and an enormous energy reserve A similar effect occurs by skidding input energy which is not easily removed from the p...

Страница 8: ...nes can cause damages to the power supply unit External Shutdown SD The power supply is set to the Shutdown mode when the control input is either shorted via a relay contact a switch contact or an NPN...

Страница 9: ...W HSEUiREG07201 240 240Vdc 3 0A 190Vdc 3 8A 720 722W Inrush Current Protection electronic The power supply unit has an electronic current limiter 230Vac 9 8Arms 13 8Apeak It is a precisely working cir...

Страница 10: ...ors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section Up to 5 pcs HSEUiREG can be paralleled The HS...

Страница 11: ...ncrease The following formula shows dv dt i C When an electronic current sink is used the output voltage remains constant at the set value The current sink provides a quick dynamic response Fig 1 Fig...

Страница 12: ...n a failure or malfunction could result in injury or death Mechanics ST HD Baseplate Cooling Temperature Management The temperature management of the HSEUiREG series provides a direct dissipation of t...

Страница 13: ...ired and for active devices 15mm space from the sidewalls For proper air convection it is necessary to install the HSEUiREG One can use the DIN Rail installation equiped standard with our patented 35m...

Страница 14: ...5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 20 12mm H6 0 20 SW 14mm 10 0mm H10 0 12 12mm H10 0 22 EB 15mm The length of ferrules is to be chosen depending on the...

Страница 15: ...tion outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to persons or thing...

Отзывы: