XW-4
(
CAS-10
)
Amateur Radio Satellite User's Manual
29
/
31
V2.0 by BA1DU
龚万骢
Sending
order
Starting
position
Data
length
Telemetry data function description
Telemetry data parsing algorithm
Range: -100
~
+100(
℃
)
4
F3W7
1Byte
Reserved
B7 of W1 is the sign bit, 0 is positive, 1 is negative; b6~b0 are numerical
bits
Range: -127
~
+127(
℃
)
5
F3W8W9
2Byte
Uplink remote control data block counter
W1 is the high byte, W2 is the low byte
Range: 0
~
65535
6
F3W10
1Byte
X-band transceiver working status
b7:
X-band transceiver transmitter switch status 1: On; 0: Off
b6:
X-band transceiver position synchronization lock indication 1:
locked; 0: lost lock
b5:
X-band transceiver remote control carrier lock indication 1: locked;
0: lost lock
b4:
X-band transceiver remote control pseudo code lock indication 1:
locked; 0: lost lock
b3:
CRC check status of X-band transceiver remote control data 1: CRC
is correct; 0: CRC is wrong
b2:
X-band transceiver remote control channel status self-check 1:
valid; 0: invalid
b1b0:
X-band transceiver remote control code group status 01: Code
group 1; 10: Code group 2
7
F3W11
1Byte
X-band transceiver AGC voltage
W1 is the integer part, W2 is the decimal part (1 decimal place)
Range: 0
~
6.6(V)
8
F3W12
1Byte
X-band transceiver transmit power level
W1 is the integer part, W2 is the decimal part (1 decimal place)
Range: 0
~
6.6(V)