Safety 

DANGER 

 MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND 

TRIPODS, TOWERS, AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, 

ANTENNAS, ETC

.  FAILURE TO PROPERLY AND COMPLETELY ASSEMBLE, INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS, 

TOWERS, AND ATTACHMENTS, AND FAILURE TO HEED WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS 

INJURY, PROPERTY DAMAGE, AND PRODUCT FAILURE.  TAKE ALL REASONABLE PRECAUTIONS TO AVOID THESE HAZARDS.  

CHECK WITH YOUR ORGANIZATION'S SAFETY COORDINATOR (OR POLICY) FOR PROCEDURES AND REQUIRED PROTECTIVE 

EQUIPMENT PRIOR TO PERFORMING ANY WORK. 

Use tripods, towers, and attachments to tripods and towers only for purposes for which they are designed.  Do not exceed design 

limits.  Be familiar and comply with all instructions provided in product manuals.  Manuals are available at www.campbellsci.com or 

by telephoning (435) 227-9000 (USA).  You are responsible for conformance with governing codes and regulations, including safety 

regulations, and the integrity and location of structures or land to which towers, tripods, and any attachments are attached.  Installation 

sites should be evaluated and approved by a qualified engineer.  If questions or concerns arise regarding installation, use, or 

maintenance of tripods, towers, attachments, or electrical connections, consult with a licensed and qualified engineer or electrician. 
General 

 

Prior to performing site or installation work, obtain required approvals and permits. Comply 
with all governing structure-height regulations, such as those of the FAA in the USA. 

 

Use only qualified personnel for installation, use, and maintenance of tripods and towers, and 
any attachments to tripods and towers.  The use of licensed and qualified contractors is 
highly recommended. 

 

Read all applicable instructions carefully and understand procedures thoroughly before 
beginning work. 

 

Wear a

 hardhat 

and

 eye protection

, and take 

other appropriate safety precautions

 while 

working on or around tripods and towers.

 

 

Do not climb

 tripods or towers at any time, and prohibit climbing by other persons. Take 

reasonable precautions to secure tripod and tower sites from trespassers. 

 

Use only manufacturer recommended parts, materials, and tools. 

Utility and Electrical 

 

You can be killed

 or sustain serious bodily injury if the tripod, tower, or attachments you are 

installing, constructing, using, or maintaining, or a tool, stake, or anchor, come in 

contact 

with

 

overhead or underground utility lines

 

Maintain a distance of at least one-and-one-half times structure height, 20 feet, or the 
distance required by applicable law, 

whichever is greater

, between overhead utility lines and 

the structure (tripod, tower, attachments, or tools). 

 

Prior to performing site or installation work, inform all utility companies and have all 
underground utilities marked. 

 

Comply with all electrical codes.  Electrical equipment and related grounding devices should 
be installed by a licensed and qualified electrician. 

Elevated Work and Weather 

 

Exercise extreme caution when performing elevated work. 

 

Use appropriate equipment and safety practices. 

 

During installation and maintenance, keep tower and tripod sites clear of un-trained or non-
essential personnel.  Take precautions to prevent elevated tools and objects from dropping. 

 

Do not perform any work in inclement weather, including wind, rain, snow, lightning, etc. 

Maintenance 

 

Periodically (at least yearly) check for wear and damage, including corrosion, stress cracks, 
frayed cables, loose cable clamps, cable tightness, etc. and take necessary corrective actions. 

 

Periodically (at least yearly) check electrical ground connections. 

WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, 

THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR 

MAINTENANCE OF TRIPODS, TOWERS, OR ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, 

ENCLOSURES, ANTENNAS, ETC.

 

Содержание WXT520

Страница 1: ...INSTRUCTION MANUAL WXT520 Weather Transmitter Revision 9 15 C o p y r i g h t 2 0 0 6 2 0 1 5 C a m p b e l l S c i e n t i f i c I n c...

Страница 2: ......

Страница 3: ...ucts to CSI CSI will return such Products by surface carrier prepaid within the continental United States of America To all other locations CSI will return such Products best way CIP port of entry per...

Страница 4: ...g container Campbell Scientific s shipping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Clea...

Страница 5: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 6: ......

Страница 7: ...on 2 5 3 Precipitation 2 5 4 Barometric Pressure 2 5 5 Air Temperature 2 5 6 Relative Humidity 3 5 7 Assembly 3 6 Installation 3 6 1 Mounting to a Campbell Scientific Crossarm 3 6 2 IP66 Mounting Devi...

Страница 8: ...Table of Contents ii A 3 Sensor Settings screen A 3 A 4 Message Settings screen A 3 Tables 6 1 Connections to Campbell Scientific Dataloggers 5 6 2 SDI 12 Commands 6...

Страница 9: ...tion Upon receipt of the WXT520 inspect the packaging and contents for damage File damage claims with the shipping company 4 Overview 4 1 Wind Speed and Direction The WXT520 s wind sensor consists of...

Страница 10: ...0 m s 1 Accuracy 0 3 m s 1 or 3 whichever is greater 0 to 35 m s1 5 36 to 60 m s 1 Response Time 0 25 s 5 2 Wind Direction Measurement Range 0 to 360 Accuracy 3 Output Resolution 1 5 3 Precipitation R...

Страница 11: ...to a Campbell Scientific Crossarm The WXT520 is mounted to a CM202 CM204 or CM206 crossarm using the 18311 mounting tube which is shipped with the WXT520 The 18311 mounting tube fits in the bottom of...

Страница 12: ...sists of a metallic band with spikes pointing upward The spike s shape and location ensure minimal interference of wind and rain measurements 1 The spikes are designed not to hurt the birds 2 While th...

Страница 13: ...te SDI 12 signal C U configured for SDI 121 C1 SDI 12 or SDI 12 Green Data ground G Green Optional heater power see note 12V or SW_Battery Pink Optional heater ground see note G Grey Not used 1 U chan...

Страница 14: ...tion Minimum Wind Direction Average Wind Direction Maximum Wind Speed Minimum Wind Speed Average Wind Speed Maximum aR2 or aM2 PTU Message Air Temperature Relative Humidity Barometric Pressure aR3 or...

Страница 15: ...m Units Hamount hits cm 2 Define Data Tables DataTable Table1 True 1 DataInterval 0 60 Min 10 WindVector 1 WindSpd WindDir FP2 False 900 0 0 FieldNames WindSpd_Mean WindDir_MeanUnitVector WindDir_SD1...

Страница 16: ...indDir_Mean WindDir_SD1 Average 1 AirTemp False Sample 1 RelHumidity Sample 1 AirPressure Totalize 1 Ramount False Totalize 1 Hamount False EndTable Main Program BeginProg Main Scan Scan 5 Sec Dalogge...

Страница 17: ...15 Loc Value1 5 1 0 Mult 6 0 0 Offset 23 Excitation with Delay P22 1 1 Ex Channel 2 0 Delay W Ex 0 01 sec units 3 50 Delay After Ex 0 01 sec units 4 0 mV Excitation Get WXT520 Values 7 9 Ta air temp...

Страница 18: ...WXT520 Weather Transmitter 10...

Страница 19: ...tor on the WXT520 2 Connect a 9 V battery to the Configuration Cable s battery clip The female contact of the battery clip is 3 On your PC run Vaisala s WXT Configuration Tool Software and go to the C...

Страница 20: ...and self diagnostic verify Enable Heating is NOT selected Heating and self diagnostics Update Interval 15 s Communication protocol select SDI 12 v1 3 User port settings Port type SDI 12 select contin...

Страница 21: ...nsor Settings screen 9 Click on the OK button 10 Go to the Message Settings Screen and verify that Message Settings are as desired The default settings are shown in FIGURE A 4 Note Hail accumulation s...

Страница 22: ...ndix A Configuring the WXT520 A 4 11 Click on the OK button 12 Close the WXT Configuration Tool 13 Remove the 9 V battery 14 Disconnect the Configuration Cable 15 Secure protective service port cap on...

Страница 23: ......

Страница 24: ...ua Apinag s nbr 2018 Perdizes CEP 01258 00 S o Paulo SP BRASIL www campbellsci com br vendas campbellsci com br Campbell Scientific Canada Corp 14532 131 Avenue NW Edmonton AB T5L 4X4 CANADA www campb...

Отзывы: