![Campbell WXT520 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/campbell/wxt520/wxt520_instruction-manual_3806653015.webp)
WXT520 Weather Transmitter
7
6.6.1.1 Example CR1000 Program
Although the following program is for the CR1000, the CR800, CR850, CR6,
CR3000, and CR5000 are programmed similarly. This program uses the “aR!”
command.
'CR1000
Public BattV
Public PTemp_C
Public WXT(7)
Alias WXT(1)=WindDir
Alias WXT(2)=WindSpd
Alias WXT(3)=AirTemp
Alias WXT(4)=RelHumidity
Alias WXT(5)=AirPressure
Alias WXT(6)=Ramount
Alias WXT(7)=Hamount
Units BattV=Volts
Units PTemp_C=Deg C
Units WindDir=Degrees
Units WindSpd=meters/second
Units AirTemp=Deg C
Units RelHumidity=%
Units AirPressure=mbar
Units Ramount=mm
Units Hamount=hits/cm^2
'Define Data Tables
DataTable(Table1,True,-1)
DataInterval(0,60,Min,10)
WindVector(1,WindSpd,WindDir,FP2,False,900,0,0)
FieldNames("WindSpd_Mean,WindDir_MeanUnitVector,WindDir_SD1")
Average(1,AirTemp,FP2,False)
Sample(1,RelHumidity,FP2)
Sample(1,AirPressure,IEEE4)
Totalize(1,Ramount,FP2,False)
Totalize(1,Hamount,FP2,False)
EndTable
'Main Program
BeginProg
'Main Scan
Scan(5,Sec,1,0)
'Dalogger Battery Voltage measurement 'BattV'
Battery(BattV)
'Panel Temperature measurement 'PTemp_C'
PanelTemp(PTemp_C,_60Hz)
'Reset WXT520 Sensor measurements
Move(WXT(),7,NaN,1)
'WXT520 Weather Transmitter measurements 'WindDir', 'WindSpd', 'AirTemp',
'RelHumidity', 'AirPressure', 'Ramount', and 'Hamount'
SDI12Recorder(WXT(),1,"0","R!",1,0)
'Call Data Tables and Store Data
CallTable Table1
NextScan
EndProg