background image

Campbell Scientific Companies 

 

 

Campbell Scientific, Inc. 

815 West 1800 North 

Logan, Utah  84321 

UNITED STATES 

www.campbellsci.com

 

• 

[email protected] 

 

 

Campbell Scientific Africa Pty. Ltd.

 

PO Box 2450 

Somerset West 7129 

SOUTH AFRICA 

www.campbellsci.co.za

 

• 

[email protected] 

 

 

Campbell Scientific Southeast Asia Co., Ltd. 

877/22 Nirvana@Work, Rama 9 Road 

Suan Luang Subdistrict, Suan Luang District 

Bangkok 10250 

THAILAND 

www.campbellsci.asia

 

• 

[email protected] 

 

 

Campbell Scientific Australia Pty. Ltd.

 

PO Box 8108 

Garbutt Post Shop QLD 4814 

AUSTRALIA 

www.campbellsci.com.au

 

• 

[email protected] 

 

 

Campbell Scientific (Beijing) Co., Ltd. 

8B16, Floor 8 Tower B, Hanwei Plaza 

7 Guanghua Road 

Chaoyang, Beijing 100004 

P.R. CHINA 

www.campbellsci.com

 

• [email protected]

 

 

 

Campbell Scientific do Brasil Ltda. 

 

Rua Apinagé

s, nbr. 2018 ─ Perdizes

 

CEP: 01258-

00 ─ 

São Paulo 

─ SP

 

BRASIL 

www.campbellsci.com.br

 

• 

[email protected]

Campbell Scientific Canada Corp.

 

14532 – 131 Avenue NW 

Edmonton AB T5L 4X4 

CANADA 

www.campbellsci.ca

 

• 

[email protected] 

 

 

Campbell Scientific Centro Caribe S.A.

 

300 N Cementerio, Edificio Breller 

Santo Domingo, Heredia 40305 

COSTA RICA 

www.campbellsci.cc

 

• [email protected]

 

 

 

Campbell Scientific Ltd.

 

Campbell Park 

80 Hathern Road 

Shepshed, Loughborough LE12 9GX 

UNITED KINGDOM 

www.campbellsci.co.uk

 

• 

[email protected] 

 

 

Campbell Scientific Ltd. 

3 Avenue de la Division Leclerc 

92160 ANTONY 

FRANCE 

www.campbellsci.fr

 

• 

[email protected] 

 

 

Campbell Scientific Ltd. 

Fahrenheitstraße 13 

28359 Bremen 

GERMANY 

www.campbellsci.de

 

• [email protected]

 

 

 

Campbell Scientific Spain, S. L. 

Avda. Pompeu Fabra 7-9, local 1 

08024 Barcelona 

SPAIN 

www.campbellsci.es

 

• 

[email protected] 

 

 

Please visit 

www.campbellsci.com

 to obtain contact information for your local US or international representative. 

Содержание WXT520

Страница 1: ...INSTRUCTION MANUAL WXT520 Weather Transmitter Revision 9 15 C o p y r i g h t 2 0 0 6 2 0 1 5 C a m p b e l l S c i e n t i f i c I n c...

Страница 2: ......

Страница 3: ...ucts to CSI CSI will return such Products by surface carrier prepaid within the continental United States of America To all other locations CSI will return such Products best way CIP port of entry per...

Страница 4: ...g container Campbell Scientific s shipping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Clea...

Страница 5: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 6: ......

Страница 7: ...on 2 5 3 Precipitation 2 5 4 Barometric Pressure 2 5 5 Air Temperature 2 5 6 Relative Humidity 3 5 7 Assembly 3 6 Installation 3 6 1 Mounting to a Campbell Scientific Crossarm 3 6 2 IP66 Mounting Devi...

Страница 8: ...Table of Contents ii A 3 Sensor Settings screen A 3 A 4 Message Settings screen A 3 Tables 6 1 Connections to Campbell Scientific Dataloggers 5 6 2 SDI 12 Commands 6...

Страница 9: ...tion Upon receipt of the WXT520 inspect the packaging and contents for damage File damage claims with the shipping company 4 Overview 4 1 Wind Speed and Direction The WXT520 s wind sensor consists of...

Страница 10: ...0 m s 1 Accuracy 0 3 m s 1 or 3 whichever is greater 0 to 35 m s1 5 36 to 60 m s 1 Response Time 0 25 s 5 2 Wind Direction Measurement Range 0 to 360 Accuracy 3 Output Resolution 1 5 3 Precipitation R...

Страница 11: ...to a Campbell Scientific Crossarm The WXT520 is mounted to a CM202 CM204 or CM206 crossarm using the 18311 mounting tube which is shipped with the WXT520 The 18311 mounting tube fits in the bottom of...

Страница 12: ...sists of a metallic band with spikes pointing upward The spike s shape and location ensure minimal interference of wind and rain measurements 1 The spikes are designed not to hurt the birds 2 While th...

Страница 13: ...te SDI 12 signal C U configured for SDI 121 C1 SDI 12 or SDI 12 Green Data ground G Green Optional heater power see note 12V or SW_Battery Pink Optional heater ground see note G Grey Not used 1 U chan...

Страница 14: ...tion Minimum Wind Direction Average Wind Direction Maximum Wind Speed Minimum Wind Speed Average Wind Speed Maximum aR2 or aM2 PTU Message Air Temperature Relative Humidity Barometric Pressure aR3 or...

Страница 15: ...m Units Hamount hits cm 2 Define Data Tables DataTable Table1 True 1 DataInterval 0 60 Min 10 WindVector 1 WindSpd WindDir FP2 False 900 0 0 FieldNames WindSpd_Mean WindDir_MeanUnitVector WindDir_SD1...

Страница 16: ...indDir_Mean WindDir_SD1 Average 1 AirTemp False Sample 1 RelHumidity Sample 1 AirPressure Totalize 1 Ramount False Totalize 1 Hamount False EndTable Main Program BeginProg Main Scan Scan 5 Sec Dalogge...

Страница 17: ...15 Loc Value1 5 1 0 Mult 6 0 0 Offset 23 Excitation with Delay P22 1 1 Ex Channel 2 0 Delay W Ex 0 01 sec units 3 50 Delay After Ex 0 01 sec units 4 0 mV Excitation Get WXT520 Values 7 9 Ta air temp...

Страница 18: ...WXT520 Weather Transmitter 10...

Страница 19: ...tor on the WXT520 2 Connect a 9 V battery to the Configuration Cable s battery clip The female contact of the battery clip is 3 On your PC run Vaisala s WXT Configuration Tool Software and go to the C...

Страница 20: ...and self diagnostic verify Enable Heating is NOT selected Heating and self diagnostics Update Interval 15 s Communication protocol select SDI 12 v1 3 User port settings Port type SDI 12 select contin...

Страница 21: ...nsor Settings screen 9 Click on the OK button 10 Go to the Message Settings Screen and verify that Message Settings are as desired The default settings are shown in FIGURE A 4 Note Hail accumulation s...

Страница 22: ...ndix A Configuring the WXT520 A 4 11 Click on the OK button 12 Close the WXT Configuration Tool 13 Remove the 9 V battery 14 Disconnect the Configuration Cable 15 Secure protective service port cap on...

Страница 23: ......

Страница 24: ...ua Apinag s nbr 2018 Perdizes CEP 01258 00 S o Paulo SP BRASIL www campbellsci com br vendas campbellsci com br Campbell Scientific Canada Corp 14532 131 Avenue NW Edmonton AB T5L 4X4 CANADA www campb...

Отзывы: