Table 8-3: Identify commands for the RainVUE-series
Type of command
Command
Sensor response
Comment
Identify
measurement for the
V
command
a
IV!
atttn
ttt: response time
(seconds)
n: # of values returned
Identify
measurement for
parameter 1 of
M
command
a
IM_001!
aAdjRain,Inches
or
aAdjRain,mm
AdjRain: adjusted or
intensity-corrected
precipitation since last
measurement
Units: inches or mm
Identify
measurement for
parameter 2 of
M
command
a
IM_002!
aRawTips,Tips
RawTips: number of raw
bucket tips since last
measurement (counts)
Units: counts
Identify
measurement for
parameter 3 of
M
command
a
IM_003!
aTotAdjRain,Inches
or
aTotAdjRain,mm
TotAdjRain: total
adjusted or total
intensity corrected
precipitation since last
reset
Units: inches or mm
Identify
measurement for
parameter 4 of
M
command
a
IM_004!
aAvgInt,Inches/Hour
or
aAvgInt,mm/Hour
AvgInt: average
precipitation intensity
since last measurement
Units: inches/hour or
mm/hour
Identify
measurement for
parameter 5 of
M
command
a
IM_005!
aMaxInt,Inches/Hour
or
aMaxInt,mm/Hour
MaxInt: maximum peak
precipitation intensity
since last measurement
Units: inches/hour or
mm/hour
RainVUE-Series SDI-12 Precipitation Sensors
17