4. QuickStart
A video that describes data logger programming using
Short Cut
is available at:
www.campbellsci.com/videos/cr1000x-data logger-getting-started-program-part-3
.
Short
Cut
is an easy way to program your data logger to measure the sensor and assign data logger
wiring terminals.
Short Cut
is available as a download on
. It is included
in installations of
LoggerNet
,
RTDAQ
, and
PC400
.
The following procedure also shows using
Short Cut
to program the sensor.
1. Open
Short Cut
and click Create New Program.
2. Double-click the data logger model.
3. In the Available Sensors and Devices box, type MetSENS or locate the sensor in the Sensors
> Meteorological > Basic Weather > MetSENS folder. Double-click the appropriate sensor
model and output. Type the correct SDI-12 Address (default is zero) or Modbus Address
(default is 41). If measuring barometric pressure, type the elevation of the site in the same
units as the Site elevation units. Default units are meters, which can be changed by clicking
on the Site elevation units box and selecting Feet.
MetSENS-Series Compact Weather Sensors
2