7.4 Sensor status code
NOTE:
For all factory repairs, customers must get an RMA number. Customers must also properly fill
out a “Declaration of Hazardous Material and Decontamination” form and comply with the
requirements specified in it. Refer to the
page at the back of this manual for more
information.
Modbus and some SDI-12 commands output a four-digit status code that indicates whether the
sensor is working properly. The following table describes these codes.
Table 7-7: Status sensor code descriptions
Code
Status
Condition
0000
OK
No fault conditions detected in measurement period
0001
Wind Measurement Fault
Wind sensor faulty
0010
Temperature
Measurement Fault
Temperature sensor faulty
0020
Dewpoint Fault
If temperature and humidity are reporting correctly, this
code indicates a main PCB fault.
0040
Humidity Fault
Humidity sensor faulty
0080
Pressure Sensor Warning
Pressure sensor reading not available/unit faulty
0100
Compass Fault
Invalid heading due to compass fault
MetSENS-Series Compact Weather Sensors