Table 7-4: MetSENS550/MetSENS600 RS-485 registers
Starting register
number
Register
count
Data
format
Label
Units
Description
40001
2
FLOAT
DIR
°
Current, uncorrected
wind direction
40003
2
FLOAT
SPEED
m/s
Current wind speed
40005
2
FLOAT
COMPASSH
°
Compass heading
of north mark
40007
2
FLOAT
PRESS
hPa
Barometric pressure
40009
2
FLOAT
RH
%
Relative humidity
40011
2
FLOAT
TEMP
°C
Air temperature
40013
2
FLOAT
DEWPOINT
°C
Dewpoint
40015
2
FLOAT
VOLT
VDC
Supply voltage
40017
2
FLOAT
AVGDIR
°
5 min. average wind
direction, updated every 30 s
40019
2
FLOAT
AVGSPEED
m/s
5 min. average wind
speed, updated every 30 s
40021
2
FLOAT
GDIR
°
Direction of wind gust
40023
2
FLOAT
GSPEED
m/s
3 s wind gust,
updated every 30 s
40025
2
FLOAT
PRECIPT
mm
Total accumulated
precipitation since powerup
40027
2
UNIT32
STATUS
7.2 SDI-12 measurements
The MetSENS-series sensors respond to the SDI-12 commands shown in
(p. 19). The
MC!
commands are the same as the
M!
commands except a cyclic redundancy check (CRC) is
included.
MetSENS-Series Compact Weather Sensors
18