![Campbell MetSENS Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/campbell/metsens-series/metsens-series_product-manual_3900888019.webp)
Table 7-1: MetSENS200 RS-485 registers
Starting register
number
Register
count
Data
format
Label
Units
Description
40001
2
FLOAT
DIR
°
Current, uncorrected
wind direction
40003
2
FLOAT
SPEED
m/s
Current wind speed
40005
2
FLOAT
COMPASSH
°
Compass heading
of north mark
40007
2
FLOAT
VOLT
VDC
Supply voltage
40009
2
FLOAT
AVGDIR
°
5 min. average wind
direction, updated every 30 s
40011
2
FLOAT
AVGSPEED
m/s
5 min. average wind
speed, updated every 30 s
40013
2
FLOAT
GDIR
°
Direction of wind gust
40015
2
FLOAT
GSPEED
m/s
3 s wind gust,
updated every 30 s
40017
2
UNIT32
STATUS
Table 7-2: MetSENS300 RS-485 registers
Starting register
number
Register
count
Data
format
Label
Units
Description
40001
2
FLOAT
PRESS
hPa
Barometric pressure
40003
2
FLOAT
RH
%
Relative humidity
40005
2
FLOAT
TEMP
°C
Air temperature
40007
2
FLOAT
DEWPOINT
°C
Dewpoint
40009
2
FLOAT
VOLT
VDC
Supply voltage
40011
2
UNIT32
STATUS
MetSENS-Series Compact Weather Sensors
16