CS725 Snow Water Equivalent Sensor
4
Power requirements:
11-15 Vdc
Power Consumption:
180 mA
Measurement Time:
Continuous; 24 hours/day
Output Format:
RS-232 (1200 to 115200 BAUD)
Default is 9600
Measurement Range:
0 – 600 mm of water equivalent
Accuracy:
±15 mm from 0 to 300 mm
±15 % from 300 to 600 mm
Resolution:
1 mm
Coverage Angle:
60° (from center)
Operating Temperature: -40°C to +40°C
Maximum Cable Length: 30 m (at 9600 BAUD or less)
Cable Type:
4 conductor
2-twisted pair
22 AWG
Stantoprene jacket
Dimensions
(w/o Collimator): Length 62 cm
Diameter 12.7 cm
Weight:
Main Body: 9.0 kg (20 lbs)
Collimator (optional): 25 kg (55 lbs)
6. Installation
It is recommended to pre-configure and test the system before taking it to the
field. Issues that are unresolved before placing instrumentation in the field will
usually be more difficult to resolve.
The CS725 must be configured using a computer before deployment.
6.1 Siting
It is important to determine if the intended installation site of the CS725 will
have appropriate sources of Potassium (K) and Thallium (Tl) to provide