Appendix C. CR3000/CR5000 Program that Controls the Heater
BeginProg
Scan
(1,Sec,0,0)
'Control the net radiometer heater.
PWM
(duty_cycle,4,250,mSec)
'Datalogger
panel
temperature.
PanelTemp
(panel_temp,250)
'Measure
battery
voltage.
Battery
(batt_volt)
'Measure the HMP45C temperature and relative humidity.
VoltDiff
(t_hmp,1,mV1000C,5,TRUE,200,250,0.1,-40)
VoltDiff
(rh_hmp,1,mV1000C,6,TRUE,200,250,0.1,0)
'Measure NR 01 Net Radiometer.
Resistance
(t_nr01,1,mV200,10,Ix1,1,1675,TRUE,TRUE,200,250,1,0)
VoltDiff
(Rs_downwell,1,mV20C,11,TRUE,200,250,NR01_SHORT_DW_CAL,0)
VoltDiff
(Rs_upwell,1,mV20C,12,TRUE,200,250,NR01_SHORT_UW_CAL,0)
VoltDiff
(Rl_down_meas,1,mV20C,13,TRUE,200,250,NR01_LONG_DW_CAL,0)
VoltDiff
(Rl_up_meas,1,mV20C,14,TRUE,200,250,NR01_LONG_UW_CAL,0)
'Find the HMP45C vapor pressure and saturation vapor pressure (kPa).
VaporPressure
(e_hmp,t_hmp,rh_hmp)
SatVP
(e_sat_hmp,t_hmp)
'Compute net radiation, albedo, downwelling and upwelling longwave radiation.
t_nr01
=
t_nr01/100
PRT
(t_nr01,1,t_nr01,1,273.15)
Rn
=
Rs_downwell-RsRl_down_meas-Rl_up_meas
albedo
=
Rs_upwell/Rs_downwell
Rl_downwell
=
Rl_do(5.67e-8*t_nr01*t_nr01*t_nr01*t_nr01)
Rl_upwell
=
Rl_(5.67e-8*t_nr01*t_nr01*t_nr01*t_nr01)
CallTable
(scratch)
If
(
scratch.Output(1,1)
)
Then
GetRecord
(scratch_out(1),scratch,1)
rh_hmp_mean
=
100*e_hmp_mean/e_sat_hmp_mean
DewPoint
(t_dew_hmp_mean,t_hmp_mean,rh_hmp_mean)
'Control the NR 01 heater using 4 Hz pulse width modulation. Below the dew
' point temperature applies 100% power. Above the dew point, power is reduced
' linearly to 20% until the dew point plus DELTA_SET_POINT_1. After the dew
' point plus DELTA_SET_POINT_1 and until the dew point plus
'
DELTA_SET_POINT_2
plus
DELTA_SET_POINT_2, the power is reduced linearly to 0%.
If ( (t_nr01 <> NaN) AND (t_dew_hmp_mean <> NaN) AND (no_heat_flag <> TRUE) ) Then
set_point_temperature
=
t_dew_h273.15
Select Case t_nr01
Case
Is
<
(
set_point_temperature
)
duty_cycle
=
1
Case Is < ( set_point_tempDELTA_SET_POINT_1 )
duty_cycle
=
MAX_DUTY_(t_nr01-(t_dew_h273.15))*SLOPE_1
Case
Is
<
(
set_point_tempDELTA_SET_DELTA_SET_POINT_2
)
duty_cycle
=
MAX_DUTY_(t_nr01-
(t_dew_h273.15+DELTA_SET_POINT_1))*SLOPE_2
C-4