CNR1 Net Radiometer
'CR5000 Series Datalogger
'ANALOG INPUT
'1H
CM3 UP - downwelling shortwave radiation signal (red)
'1L
CM3 UP - downwelling shortwave radiation signal reference (blue)
'gnd
CNR1 shield (clear)
'2H
CM3 DOWN - upwelling shortwave radiation signal (white)
'2L
CM3 DOWN - upwelling shortwave radiation signal reference (black)
'3H
CG3 UP - downwelling longwave radiation signal (gray)
'3L
CG3 UP - downwelling longwave radiation signal reference (yellow)
'4H
CG3 DOWN - upwelling longwave radiation signal (brown)
'4L
CG3 DOWN - upwelling longwave radiation signal reference (green)
'6H
CNR1 Pt100 (yellow)
'6L
CNR1 Pt100 (green)
'Current Excitation
'IX1
CNR1 Pt100 (red)
'IXR
CNR1 Pt100 (blue)
'Declare Variables and Units
Public Batt_Volt
Public CM3Up
Public CM3Dn
Public CG3Up
Public CG3Dn
Public CNR1TC
Public CNR1TK
Public NetRs
Public NetRl
Public Albedo
Public UpTot
Public DnTot
Public NetTot
Public CG3UpCo
Public CG3DnCo
Units Batt_Volt=Volts
Units CM3Up=W/meter²
Units CM3Dn=W/meter²
Units CG3Up=W/meter²
Units CG3Dn=W/meter²
Units CNR1TC=Deg C
Units CNR1TK=K
Units NetRs=W/meter²
Units NetRl=W/meter²
Units Albedo=W/meter²
Units UpTot=W/meter²
Units DnTot=W/meter²
Units NetTot=W/meter²
Units CG3UpCo=W/meter²
Units CG3DnCo=W/meter²