CNR1 Net Radiometer
6.2.3 Example 3, CR23X Program Using Differential Channels
Program Example 3 requires six differential channels and the 4WPB100
module to measure the four radiation outputs and the Pt-100 temperature
sensor. The program measures the sensors every 2 seconds and calculates and
stores the following data to final storage every 60 minutes:
Array
ID
Year
Julian
Day
Hour/Minute
Avg CM3 Up (shortwave radiation)
Avg CM3 Down (shortwave radiation)
Avg CG3 Up (longwave radiation)
Avg CG3 Down (longwave radiation)
Avg CNR1 temperature (degrees C)
Avg CNR1 temperature (degrees K)
Avg Net shortwave radiation
Avg Net longwave radiation
Avg
Albedo
Avg Total Net radiation
Avg temperature corrected CG3 Up
Avg temperature corrected CG3 Down
Wiring for Program Example 3
Color
Function
Example CR23X
Program
Channels Used
Red CM3
Up
Signal 1H
Blue
CM3 Up Reference
1L
White
CM3 Down Signal
2H
Black
CM3 Down Reference
2L
Grey or Orange
CG3 Up Signal
3H
Yellow CG3
Up
Reference
3L
Brown
CG3 Down Signal
4H
Green CG3
Down
Reference
4L
Shield Shield
Pt-100 Temperature Sensor Connections to 4WPB100 and Datalogger
Color
Function
4WPB100
CR23X
Black Wire
EX1
H
5H
Red
Pt-100 Exci
L
5L
Blue
Pt-100 Excitation -
G
Yellow Pt-100
Signal
+
6H
Green Pt-100
Signal
-
6L
17