Diameter:
3.0 cm (1.2 in)
Length:
16.6 cm (6.5 in)
7. Installation
If you are programming your data logger with
Short Cut
, skip
(p. 7) and
7).
Short Cut
does this work for you. See
(p. 2) for a tutorial.
7.1 Wiring
Connect the wires in the order shown in the following table.
Table 7-1: Wire color, function, and data logger connection
Wire color
Wire function
Data logger connection
White
SDI-12 signal
C, SDI-12, or U configured for SDI-12
1
Red
Power
12V
Black
Power ground
G
Clear
Shield
G
1
U and C terminals are automatically configured by the measurement instruction.
If multiple SDI-12 sensors are connected to a data logger, Campbell Scientific recommends using
separate terminals when possible. However, multiple SDI-12 sensors can connect to the same
data logger control (C) or universal (U) terminal. Each must have a unique SDI-12 address. Valid
addresses are 0 through 9, a through z, and A through Z.
For CR6 and CR1000X data loggers, triggering conflicts may occur when a companion terminal is
used for a triggering instruction such as
TimerInput()
,
PulseCount()
, or
WaitDigTrig()
.
For example, if this product is connected to C3 on a CR1000X, C4 cannot be used in the
TimerInput()
,
PulseCount()
, or
WaitDigTrig()
instructions.
7.2 Programming
Short Cut
is the best source for up-to-date programming code for Campbell Scientific data
loggers. If your data acquisition requirements are simple, you can probably create and maintain a
data logger program exclusively with
Short Cut
. If your data acquisition needs are more complex,
ClariVUE™10 Side-Scatter Turbidity Sensor
7